CONTAP-437510: CFBMC-6646 - ONTAP AlphaUser Synced State showing SYNC FAILED
Issue
- The LED on the NetApp lights up for some time. No errors (FRU etc) are visible.
- No sensors report failures
- No error messages pointing to BMC, controller or PCI cards are present
- After performing a BMC wipe-clean configuration, sensor indicates to be failing in sync for one of the nodes, but there is no faulty sensor present.
DEAU1STNAP-CL1::*> run -node nap12 -command environment status
Sensor Name State Current Critical Warning Warning Critical
Reading Low Low High High
-------------------------------------------------------------------------------------------------
IPMI Heartbeat IPMI_HB_OK
ONTAP AlphaUser Synced State SYNC_FAILED
ONTAP Boot State NORMAL
- Partner node shows all values correct, and AlphaUser Synced State shows "SYNCED"