CHW-3751: IONIC 100G NIC becomes unresponsive causing panic
Issue
Node panics hours after partner node panicked during cluster switch firmware upgrade
PANIC: Process secd unresponsive for 180 seconds in process nodewatchdog on release 9.16.1P7 (C) on Thu Mar 12 05:11:13 CET 2026
Numerous vifmgr.rpc.nblade.timeouts:error messages seen in the EMS log
<118>[14607841] 3/12/2026 02:04:20 ntapM01-04 ERROR vifmgr.rpc.nblade.timeouts: The virtual interface manager is not receiving responses from the node's networking component.
<118>[14607841] 3/12/2026 02:04:08 ntapM01-04 ERROR vifmgr.reach.err: Network port e0b on node ntapM01-04 encountered errors while scanning for reachability. Reachability was detected to the following broadcast domains: -.
<118>[14607841] 3/12/2026 02:03:08 ntapM01-04 ERROR vifmgr.reach.err: Network port e0a on node ntapM01-04 encountered errors while scanning for reachability. Reachability was detected to the following broadcast domains: -.
<118>[14607841] 3/12/2026 02:02:16 ntapM01-04 ERROR vifmgr.rpc.nblade.timeouts: The virtual interface manager is not receiving responses from the node's networking component.
<118>[14607841] 3/12/2026 02:02:08 ntapM01-04 ERROR vifmgr.reach.err: Network port e0M on node ntapM01-04 encountered errors while scanning for reachability. Reachability was detected to the following broadcast domains: -.
Dual 100G Ethernet Controller IONIC NIC is on firmware 1.4.0-E-114