CHW-3318: PSU unit shows sensors "not-available" before and after replacement. PSU is confirmed to be good

Views:
16
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

Issue

The PSU2 unit reports "not-available" sensors when attempting to retrieve system sensors information from BMC and ONTAP prompts.

  • When reviewing the outputs for system sensors of the affected node it shows the PSU sensors as being "not-available":

BMC affected-node-name> system sensors show
PSU1:
PSU1_Status | 0x0 | discrete | Ready | na | na | na | na
PSU1_12V_IOUT | 32.000 | Amps | ok | 0.000 | 0.000 | 165.000 | 173.000
PSU1_12V_VOUT | 12.060 | Volts | ok | 10.980 | 11.400 | 12.900 | 13.500
PSU1_IIN | 1.800 | Amps | ok | 0.000 | 0.000 | 14.100 | 15.000
PSU1_PIN | 424.000 | Watts | ok | na | na | na | na
PSU1_POUT | 392.000 | Watts | ok | na | na | na | na
PSU1_Type | 2.000 | unspecified | ok | na | na | na | na
PSU1_VIN | 228.000 | Volts | ok | 84.000 | 90.000 | 264.000 | 276.000
PSU2:
PSU2_Status | na | discrete | na | na | na | na | na
PSU2_12V_IOUT | na | Amps | na | 0.000 | 0.000 | 165.000 | 173.000
PSU2_12V_VOUT | na | Volts | na | 10.980 | 11.400 | 12.900 | 13.500
PSU2_IIN | na | Amps | na | 0.000 | 0.000 | 14.100 | 15.000
PSU2_PIN | na | Watts | na | na | na | na | na
PSU2_POUT | na | Watts | na | na | na | na | na
PSU2_Type | na | unspecified | na | na | na | na | na
PSU2_VIN | na | Volts | na | 84.000 | 90.000 | 264.000 | 276.000

 
::> system node environment sensors show -node affected-node-name -state !normal
Node Sensor State Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi
---- --------------------- ------ ----------- -------- -------- ------- -------
affected-node-name
PSU2 Present not-available
PSU2 Output OK not-available
PSU2 Input OK not-available
PSU2 In Volt not-available
- mV 84000 90000 264000 276000
PSU2 In Curr not-available
- mA 0 - 14100 15000
PSU2 12V Out Volt not-available
- mV 10980 11400 12900 13500
PSU2 12V Out Curr not-available
- mA 0 - 165000 173000
PSU2 In Pwr not-available
- W - - - -
PSU2 Out Pwr not-available
- W - - - -
PSU2 Type not-available
10 entries were displayed.

  • Replacement PSU continues to display the same results
  • System Health commands show the cluster as healthy
  • Swapping PSU with a known-working unit from partner node indicates that the both PSU units are good, but the error remains in the PSU slot.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.