StorageBridgePortDown_Alert reported in Stretch MetroCluster system
Applies to
- ONTAP 9
- Stretch MetroCluster
Issue
- One of the FC ports on a node is down:
slot 1: FC Host Adapter 1c (Emulex XE201 rev. 48, <DOWN>)Board name:        111-02455Serial Number:     FCXXXXXX77Firmware rev:      11.4.277.0Host Port Id:      N/AFC Node Name:      2:000:00109b:25b9bcFC Port Name:      1:000:00109b:25b9bcSFP Vendor:        AVAGOSFP Part Number:   AFBR-57F5MZ-NA1SFP Serial Number: AA1XXXXX1RDSFP Capabilities:  4, 8 or 16 GbitLink Data Rate:    N/A- The ATTO bridge FC port that is connected to the above node port is also down and the bridge reports the below error:
ATTO_161.XXX.XX.XXX(200000XXXXXXXXX):FC_PORT_1 is Offline.Cluster1::> storage bridge show
                                       Is        Monitor
Bridge                   Symbolic Name Monitored Status  Vendor Model                 Bridge WWN
------------------------ ------------- --------- ------- ------ --------------------- ----------------
ATTO_161.XXX.XX.XX4      Node1-br1
                                       true      ok      Atto   FibreBridge 7500N     200XXXXXXXXX7c00
ATTO_161.XXX.XX.XX5      Node1-br2
                                       true      ok      Atto   FibreBridge 7500N     200XXXXXXXXX7900
ATTO_161.XXX.XX.XX6      Node1-br3
                                       true      ok      Atto   FibreBridge 7500N     200XXXXXXXXX6600
ATTO_161.XXX.XX.XX7      Node1-br4
                                       true      error   Atto   FibreBridge 7500N     200XXXXXXXXX7b40                      
4 entries were displayed.- The affected node is transitioned to "Mixed Path" configuration:
NetApp Release 9.3P7: Wed Jul 25 06:16:06 EDT 2018System ID: 0538031811 (Node-01)System Serial Number: 45XXXXXXXX8 (Node-01)System Rev: A4System Storage Configuration: Mixed-Path- StorageBridgePortDown_Alertand- FC-AL LINK_FAILUREalerts reported in the event logs:
[Node-01: slifc_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 1c.[Node-01: lhm_main: callhome.fc.al.link:alert]: Call home for FC-AL LINK_FAILURE (1c)[Node-01: schmd: hm.alert.raised:alert]: Alert Id = StorageBridgePortDown_Alert , Alerting Resource = 200XXXXXXXXX7b40 raised by monitor system-connect[Node-01: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process schm: StorageBridgePortDown_Alert[200XXXXXXXXX7b40].- The bridge health is degraded:
Cluster1::> system health subsystem  showSubsystem         Health----------------- ------------------SAS-connect       okEnvironment       okMemory            okService-Processor okSwitch-Health     okCIFS-NDO          okMotherboard       okIO                okMetroCluster      okMetroCluster_Node okFHM-Switch        okFHM-Bridge        degradedSAS-connect_Cluster ok13 entries were displayed.- The link between the affected FC ports on the node and ATTO bridge remain down despite SFP and cable replacement.
- On swapping the cables between a known good node port and the affected ATTO, the link on the ATTO bridge comes online.