Skip to main content
NetApp Knowledge Base

LUN move with a tiered volume is not optimized

Views:
11
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

Applies to

ONTAP 9
Fabricpool
LUN move operations

Issue

When moving a LUN from a tiered aggregate to another aggregate attached to the same capacity tier, data is being pulled back from the capacity tier to the performance tier resulting in a 'non-optimized' move.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.