ANDU paused after callhome.nve.digest.mismatch alert was triggered
Applies to
- Automated Non-Disruptive Upgrade (ANDU) from versions prior to ONTAP 9.7 to ONTAP 9.11P8.
 - NetApp Volume Encryption (NVE) with External Key Manager
 
Issue
- A 
callhome.nve.digest.mismatcherror is reported in the event log:- 
        
Mon Jun 19 14:46:37 +0100 [cluster1-01: mgwd: callhome.nve.digest.mismatch:EMERGENCY]: Call home for NVE KEY DIGEST MISMATCH. key ID: 0000000000000000020000000000050068bb669ce5fbb5807e52b7xxxxxxxxxx0000000000000000, Key Server: keyserver.com:5696. 
 - 
        
 - Followed by the ANDU pausing:
    
Mon Jun 19 15:02:15 +0100 [cluster1-01: upgrademgr: upgrademgr.update.pausedErr:error]: The automated update of the cluster has been paused due to the following reason: Node "cluster1-01": Error: {Giveback of SFO aggregate is vetoed.}, Action: {Use the "storage failover show-giveback" command to view detailed veto status information. Correct the vetoed subsystem. Use the "storage failover giveback -ofnode "cluster1-02" command to complete the giveback.}.Mon Jun 19 15:02:15 +0100 [cluster1-01: notifyd: callhome.andu.pausederr:alert]: params: {'epoch': '19d7bf38-ca12-4417-a418-xxxxxxxxxxxx', 'subject': 'AUTOMATED NDU PAUSED ON NODE: cluster1-01'}
 