Skip to main content
NetApp Knowledge Base

What is the definition of "CN1610 temperature default threshold"?

Views:
257
Visibility:
Public
Votes:
4
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • Cluster Network Switch - CN1610
  • ONTAP 8
  • ONTAP 9

Answer

You can monitor the physical status of the switch by observing the status of the fans, power supply status, and temperature. Here, below information covers Temperature threshold which is measured in degrees Celsius.

The temperature sensors and power levels are read about every 30 seconds. Fan speeds are also updated in accordance with the temperature status level.

Critical:

  • Over-temperature:

If a temperature sensor reaches 61C, a timer is started and the admin is warned with an ALERT level message being logged with the message 'Critical temperature reading' . This timer expires in two minutes. If the temperature falls to 60C or below, the timer is stopped. Upon expiry of the timer, the system is shutdown by removing power.

  • Under-temperature:

If a temperature sensor reaches 0C, a timer is started and the admin is warned with an ALERT level message being logged with the message 'Critical temperature reading' . This timer expires in two minutes. If the temperature rises above 0C, the timer is stopped. Upon expiry of the timer, the system is shutdown by removing power.

  • Warning threshold:

Temperature rises to 54C Note: It will not leave the warning state until the temperature falls to 49 or below. This is intended to reduce oscillations between NORMAL and WARNING state. The result is that temperatures 50-53C can show either NORMAL or WARNING '

The following example displays normal output for the "show environment"
command:
(switch_name) #show environment
Temp (C)....................................... 40
Fan Speed, RPM................................. 9300
Fan Duty Level................................. 75%
Temperature traps range: 0 to 60 degrees (Celsius)

Temperature Sensors:
Unit     Sensor  Description       Temp (C)    State           Max_Temp (C)
----     ------  ----------------  ----------  --------------  --------------
1        1       CPU & SWITCH      40          Normal          48
1        2       Left PHY's        40          Normal          42
1        3       Right PHY's       0           Warning         46

Additional Information

This threshold cannot be modified.

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.