UNSUPPORTED SWITCH_ALERT reported following ONTAP upgrade for supported CN1610 switches
Applies to
- ONTAP Upgrade
- ONTAP 9.8
- CN1610
- FastPath Version (1.3.0.3)
Issue
- ONTAP upgrade from 9.7Px to 9.8Px
- EMS alerts triggered and cleared immediately:
cshmd: hm.alert.raised:alert]: Alert Id = UnsupportedSwitch_Alert , Alerting Resource = Clusterswitch1 raised by monitor ethernet-switch
cshmd: hm.alert.cleared:notice]: Alert Id = UnsupportedSwitch_Alert , Alerting Resource = Clusterswitch1 cleared by monitor ethernet-switch
cshmd: hm.alert.raised:alert]: Alert Id = UnsupportedSwitch_Alert , Alerting Resource = Clusterswitch2 raised by monitor ethernet-switch
cshmd: hm.alert.cleared:notice]: Alert Id = UnsupportedSwitch_Alert , Alerting Resource = Clusterswitch2 cleared by monitor ethernet-switch
- Cluster health monitor corrective actions report:
::> system health alert definition show -node <nodename> -monitor cluster-switch -alert-id UnsupportedSwitch_Alert
Node: <node name>
Monitor: cluster-switch
Class of Alert: UnsupportedSwitch_Alert
Severity of Alert: Major
Probable Cause: Configuration_error
Probable Cause Description: Unsupported cluster switch is detected.
Possible Effect: Communication problems and cluster connectivity issues occur.
Corrective Actions: Unsupported cluster switch "$(cluster_switch_support.device)" found. Connect a supported cluster switch to cluster network.
Subsystem Name: Switch-Health
- Validated switch model, firmware version, ONTAP version compatibility in NetApp Hardware Universe