Switch unreachable alert causes switch health to be degraded
Applies to
- ONTAP 9
- FAS/AFF Systems
- Cluster Network Switches
Issue
- SwitchUnreachable_Alert is reported on a cluster switch.
- The reported cluster switch is not being monitored with the following reason:
::> system switch ethernet show
Switch Type Address Model
--------------------------- ------------------ ---------------- ---------------
Switch_1(FLMXXXXXXXX) cluster-network 19.225.XXX.XX NX3132V
Serial Number: FLMXXXXXXXX
Is Monitored: false
Reason: IP address not reachable
Software Version: Cisco Nexus Operating System (NX-OS) Software, Version 7.0(3)I4(1)
Version Source: CDP
- In some cases, the health alert may be raised and cleared automatically within a few minutes:
[Node1: cshmd: hm.alert.raised:alert]: Alert Id = SwitchUnreachable_Alert , Alerting Resource = SW1 raised by monitor ethernet-switch
[Node1: cshmd: hm.alert.cleared:notice]: Alert Id = SwitchUnreachable_Alert , Alerting Resource = SW1 cleared by monitor ethernet-switch
- From
SYSTEM-HEALTH-ALERT.XML
section of the autosupport, the following details are seen:
Alert ID SwitchUnreachable_Alert
Subsystem Switch-Health
Perceived Severity Major
Alerting Resource Switch_1(FLMXXXXXXXX)
Description The specified IP address "19.225.XXX.XX" for the ethernet switch "Switch_1(FLMXXXXXXXX)" is not reachable from the local node.
Possible Effect Monitoring of the switch and log collection will not function.
- The switch health is degraded because of this alert:
::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor ok
Switch-Health degraded
CIFS-NDO ok
Motherboard ok