Issue

  • ONTAP reports system health alerts for switch ports not used by the cluster, specifically:
EMS Alerts:
Wed XXX XX 07:01:14 +0200 [Nodea:cshmd:hm.alert.raised:alert]: AlertId=SwitchIfDeviceDisconnected_Alert, AlertingResource=Switch1/Slot:0 Port:11 25G-Level raised by monitor ethernet-switchWed XXX XX 07:01:14 +0200 [Nodea:cshmd:hm.alert.raised:alert]: AlertId=SwitchIfDeviceDisconnected_Alert, AlertingResource=Switch2/Slot:0 Port:11 25G-Level raised by monitor ethernet-switch

System health alert:
Monitor	 : ethernet-switch	ethernet-switch
Alert ID :	SwitchIfDeviceDisconnected_Alert
Alerting Resource :	Switch1/Slot: 0 Port: 11 25G - Level	
Subsystem :	Switch-Health
Indication Time : Fri XXX 0X X0:13:XX 20XX
Perceived Severity : Degraded
AutoSupport Triggered : false
Probable Cause : Loss_of_signal
Corrective Actions	:
1) Check the physical connections between the switch and the connected devices. Ensure that cables are properly connected and not damaged.
2) Inspect the switch interface configuration for any inconsistencies or errors that may cause the interface to go down. Correct any misconfigurations found.
3) Verify the performance and health of the connected devices, as well as the switch itself. Check for any hardware issues or malfunctions that may cause the interface to change its operational status to down.
4) Monitor the network traffic on the affected interface to identify any unusual patterns or excessive loads that may contribute to the disconnection.	
  1. Ports 0/11 and 0/12 on both cluster switches (Switch1 and Switch2) reported flapping or device-disconnected alerts.
  2. These ports are not mapped to any ONTAP cluster node and are not used for cluster interconnect traffic.
  3. SFPs/cables are physically connected to these disabled ports.

  • Switch-Health shows "degraded"
::*> system health subsystem show
Subsystem         Health
----------------- ------------------
SAS-connect       ok
Environment       ok
Memory ok
Service-Processor ok
Switch-Health     degraded
CIFS-NDO          ok
Motherboard       ok
IO                ok
MetroCluster ok
MetroCluster_Node ok
FHM-Switch        ok
FHM-Bridge        ok
SAS-connect_Cluster ok

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.