Skip to main content
NetApp Knowledge Base

Cluster connectivity fails after RCF C3232Q cluster switch update

Views:
153
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
hw
Last Updated:

Applies to

  • Cisco NX3232C Cluster Network Switch (CNS)
  • Cisco NX3132 Cluster Network Switch (CNS)
  • NX-OS firmware update
  • RCF firmware update

Issue

  • Migrating cluster LIFs to the updated switch, the cluster ping-cluster shows broken paths. Example for 4 nodes:
::> set advanced
::*> cluster ping-cluster -node node_name-2
Host is node_name-2
Getting addresses from network interface table...
Cluster node_name-2_clus1 169.254.97.141 node_name-2 e4a
Cluster node_name-2_clus2 169.254.119.137 node_name-2 e4e
...
Basic connectivity succeeds on 6 path(s)
Basic connectivity fails on 6 path(s)
...
Larger than PMTU communication succeeds on 6 path(s)
RPC status:
6 paths up, 0 paths down (tcp check)
6 paths up, 0 paths down (udp check)
  • Each node reports an error similar to:

[node_name-1: vifmgr: vifmgr.cluscheck.droppedall:debug]: Total packet loss when pinging from cluster lif node_name-1_clus2 (node node_name-1) to cluster lif node_name-2_clus1 (node node_name-2).
[node_name-1: vifmgr: callhome.clus.net.degraded:debug]: Call home for CLUSTER NETWORK DEGRADED: Total Packet Loss - Ping failures detected between node_name-1_clus1 ( 169.254.243.146 ) on node_name-1 and node_name-2_clus2 ( 169.254.43.139 ) on node_name-2

  • cluster ping-cluster fails when ports ping others connected to a different switch.
  • cluster ping-cluster are ok when ports ping others connected to the same switch.
  • ISL ports in eth1/31-32 report properly and transmit data in the # show interface eth1/31-32 output

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.