Cisco 9332D-GX2B ISL down due to speed mismatch
Applies to
- ONTAP 9
- Cisco 9332D-GX2B
Issue
- SwitchIslIfDownWarn_Alert triggers for both cluster switches
show interface statusfrom the switches shows the ISL down and suspended:
Port Name Status Vlan Duplex Speed --------------------------------------------------------------------------------Eth1/31 LOCAL_ISL Switch 4 suspnd trunk auto autoshow interface <port>displays no errors on the portshow loggingoutput shows unsupported SFP messages, and link failure:
2026 Jun 25 18:55:52 switch_1 %ETHPORT-5-IF_HARDWARE: Interface Ethernet1/31, hardware type changed to 100G2026 Jun 25 18:55:52 switch_1 %ETHPORT-3-IF_UNSUPPORTED_TRANSCEIVER: Transceiver on interface Ethernet1/31 is not supported2026 Jun 25 20:53:14 switch_1 %ETH_PORT_CHANNEL-5-PORT_DOWN: port-channel1: Ethernet1/31 is down2026 Jun 25 20:53:14 switch_1 %ETHPORT-5-IF_DOWN_LINK_FAILURE: Interface Ethernet1/31 is down (Link failure)- Supported SFPs are replaced, but there is a temporary speed mismatch due to one end being 100G and the other 400G, resulting in link suspension:
2026 Jul 31 16:33:45 switch_1 %ETHPORT-5-IF_HARDWARE: Interface Ethernet1/31, hardware type changed to No-Transceiver2026 Jul 31 16:34:01 switch_1 %ETHPORT-5-IF_HARDWARE: Interface Ethernet1/31, hardware type changed to 400G2026 Jul 31 16:34:07 switch_1 %ETH_PORT_CHANNEL-5-PORT_SUSPENDED: port-channel1: Ethernet1/31 is suspended2026 Jul 31 16:34:07 switch_1 %ETH_PORT_CHANNEL-5-IF_DOWN_SUSPENDED_BY_SPEED: Interface Ethernet1/31 is down (Suspended due to incompatible speed