Boot flash device issue in N3K-C3132Q-V network switch
Applies to
- N3K-C3132Q-V
- NX-OS 7.0(3)I4(1)
- Switch uptime over 1000 days
Issue
While trying to update the firmware on the switch, following error is encountered:
switch01 %KERN-2-SYSTEM_MSG: [40586834.072367] EXT4-fs (sda3): Remounting filesystem read-only - kernel
switch01 %KERN-3-SYSTEM_MSG: [40586834.072370] EXT4-fs (sda3): previous I/O error to superblock detected - kernel
switch01 %DIAGCLIENT-2-EEM_ACTION_HM_SHUTDOWN: Test <BootFlash> has been disabled as a part of default EEM action
switch01 %DIAGCLIENT-2-EEM_ACTION_HM_SHUTDOWN: Test
has been disabled as a part of default EEM action
switch01 %DEVICE_TEST-2-COMPACT_FLASH_FAIL: Module 1 has failed test BootFlash 5 times on device BootFlash due to error Failure