AutoSupport Message: SwitchTemperature_Alert
Applies to
- ONTAP 9
- Cisco cluster network switches
Issue
- A
SwitchTemperatureWarn_Alert
autoSupport alert is sent when the switch's sensor temperature threshold is crossed.
[node-1: mgwd: callhome.hm.alert.minor:error]: Call home for Health Monitor process cshm: SwitchTemperatureWarn_Alert[cluster-sw01(FDXXXXXXXZD)/module-1 BACK].
- Switch logs indicate the current temperature crossing threshold.
cluster-sw01# show environment
Temperature:
--------------------------------------------------------------------
Module Sensor MajorThresh MinorThres CurTemp Status
(Celsius) (Celsius) (Celsius)
--------------------------------------------------------------------
1 FRONT 80 70 44 Ok
1 BACK 70 42 44 MinorAlarm
1 CPU 90 80 58 Ok
1 Heavenly 110 90 66 Ok
SwitchTemperatureCritical_Alert
AutoSupport alert might also be seen in conjunction with this issue.- The switch may shut down if the switch temperature continues past the temperature threshold