AutoSupport Message: SwitchTemperatureWarn_Alert
Applies to
- ONTAP 9
 - Cluster Network Switches
 
Issue
- A 
SwitchTemperatureWarn_AlertautoSupport alert is sent when the switch's sensor temperature threshold is crossed. 
[node-1: mgwd: callhome.hm.alert.minor:error]: Call home for Health Monitor process cshm: SwitchTemperatureWarn_Alert[cluster-sw01(FDXXXXXXXZD)/module-1 BACK].
- Switch logs indicate the current temperature crossing threshold.
 
cluster-sw01# show environment
Temperature:
--------------------------------------------------------------------
Module   Sensor        MajorThresh   MinorThres   CurTemp     Status
                       (Celsius)     (Celsius)    (Celsius)
--------------------------------------------------------------------
1        FRONT           80              70          44         Ok
1        BACK            70              42          44         MinorAlarm
1        CPU             90              80          58         Ok
1        Heavenly        110             90          66         Ok
SwitchTemperatureCritical_AlertAutoSupport alert might also be seen in conjunction with this issue.- The switch may shut down if the switch temperature continues past the temperature threshold
 