WWPN not getting logged in to brocade switch
Applies to
Issue
- WWPN is not getting detected after the cable is plugged in to brocade switch and port going in to
In_Sync
state
Index Port Address Media Speed State Proto
==================================================
35 35 01xx00 id N32 In_Sync FC
=============
Port 35:
=============
Identifier: 3 SFP
Connector: 7 LC
Transceiver: 6804406000000000 8,16,32_Gbps M5 sw Inter,Short_dist
....
Vendor Name: BROCADE
Vendor OUI: 00:05:1e
Vendor PN: 57-1000333-01
...
Temperature: 59 Centigrade
Current: 0.000 mAmps
Voltage: 3291.7 mVolts
RX Power: -2.9 dBm (507.2uW)
TX Power: -1.5 dBm (715.4 uW)
- Rx and Tx of the SFPs are in optimal range
- When the cable is moved to different free ports wwpn is still not logged in
- Replaced the cable on the switch port to the host, wwpn is still not logged in
Link fail, loss sync
errors were reported on the porterrshow and seemed to be historic
/fabos/cliexec/porterrshow:
frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs uncor
tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err err
32: 4.2g 4.2g 0 0 0 0 0 0 0 2 35.7k 17.9k 411 0 0 0 0 0 16.6k
33: 2.9g 668.2m 0 0 0 0 0 0 0 1 35.5k 17.9k 119 0 0 0 0 0 9.4k
2023/07/20-23:34:32, [PORT-1003], 61891, FID 128, WARNING, G620B, Port 33 Faulted because of many Link Failures.
2023/07/20-23:37:54, [PORT-1003], 61897, FID 128, WARNING, G620B, Port 33 Faulted because of many Link Failures.
2023/07/20-23:41:16, [PORT-1003], 61903, FID 128, WARNING, G620B, Port 33 Faulted because of many Link Failures.
2023/07/20-23:44:43, [PORT-1003], 61909, FID 128, WARNING, G620B, Port 33 Faulted because of many Link Failures.
- When the same cable is moved to different switch wwpn is getting logged in