Issue

  • Increased temperature in the switch and leading to higher fan rpm which is leading to very noisy environment 
  • Event logs shows the blade temperature is going high

2020/01/13-13:38:35:993021, [HIL-5600], 398250/0, M1 | Active, WARNING, VDX6740T-1G, Fan speed changing per environmental specifications.  Reason: Blade in max temp range (currently max fan speed)., hil_policy_chas, line: 559, comp:emd, ltime:2020/01/13-13:38:35:992849
2020/01/13-13:38:53:586722, [HIL-5600], 398252/0, M1 | Active, WARNING, VDX6740T-1G, Fan speed changing per environmental specifications.  Reason: Blade in max temp range (currently max fan speed)., hil_policy_chas, line: 559, comp:emd, ltime:2020/01/13-13:38:53:586514
2020/01/13-13:39:11:182804, [HIL-5600], 398254/0, M1 | Active, WARNING, VDX6740T-1G, Fan speed changing per environmental specifications.  Reason: Blade in max temp range (currently max fan speed)., hil_policy_chas, line: 559, comp:emd, ltime:2020/01/13-13:39:11:182586

  • The fan speed in this example shows at 9000RPM, where as the normal operating range is 5000 to 6000rpm range

NOSCLI show environment fan:
Mon Jan 13 13:16:35 GMT 2020
********************************************************
show environment fan:
Rbridge-id: 1
Fan 1 is Ok, speed is 9132 RPM
Fan 2 is Ok, speed is 9174 RPM
Fan 3 is Ok, speed is 9049 RPM
Fan 4 is Ok, speed is 9090 RPM

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.