Skip to main content
NetApp Knowledge Base

Brocade switch status changed from HEALTHY to CRITICAL due to faulty Power supply

Views:
754
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

Applies to

  • Brocade G620 switch
  • Brocade G720 switch

Issue

  • Switch status has changed from HEALTHY to CRITICAL as per errdump log on Brocade switch.
  • psshow output shows power supply1 is faulty.

psshow -v       :
Power Supply #1 is faulty
Power Supply #2 is OK

  • sensorshow output shows sensor10(power supply) is faulty.

sensorshow        :
sensor  1: (Temperature) is Ok, value is 33 C
sensor  2: (Temperature) is Ok, value is 41 C
sensor  3: (Temperature) is Ok, value is 37 C
sensor  4: (Temperature) is Ok, value is 36 C
sensor  5: (Temperature) is Ok, value is 37 C
sensor  6: (Temperature) is Ok, value is 32 C
sensor  7: (Temperature) is Ok, value is 56 C
sensor  8: (Fan        ) is Ok,speed is 8141 RPM
sensor  9: (Fan        ) is Ok,speed is 8043 RPM
sensor 10: (Power Supply) is Faulty
sensor 11: (Power Supply) is Ok

 

  • errdump output shows below errors being reported for power supply.

2023/09/17-04:27:09, [EM-1034], 403, CHASSIS, ERROR, BrocadeG620, PS 1 set to faulty, rc=2000e.
2023/09/17-04:28:00, [MAPS-1021], 404, FID 128, WARNING, NSWNT-DC-B, RuleName=defCHASSISBAD_PWR_CRIT, Condition=CHASSIS(BAD_PWR>=1), Obj:Chassis [ BAD_PWR,1] has contributed to switch status CRITICAL.
2023/09/17-04:28:00, [MAPS-1020], 405, FID 128, WARNING, NSWNT-DC-B, Switch wide status has changed from HEALTHY to CRITICAL.

 

  • Multiple alerts related to PSU and Fan faulty logged under errdump.

2024/09/18-12:50:25, [EM-1034], 326, CHASSIS, ERROR, BrocadeG720, PS 2 set to faulty, rc=2000e.
2024/09/18-12:50:25, [EM-1034], 327, CHASSIS, ERROR, BrocadeG720, Fan 2 set to faulty, rc=2000e.

2024/09/18-12:50:29, [HIL-1301], 328, CHASSIS, WARNING, BrocadeG720, 1 blower failed or missing. Replace failed or missing blower assembly immediately.
2024/09/18-12:51:23, [MAPS-1021], 329, FID 128, WARNING, BrocadeG720, RuleName=defCHASSISBAD_PWR_CRIT, Condition=CHASSIS(BAD_PWR>=1), Obj:Chassis [ BAD_PWR,1] has contributed to switch status CRITICAL.
2024/09/18-12:51:23, [MAPS-1021], 330, FID 128, WARNING, BrocadeG720, RuleName=defCHASSISBAD_FAN_MARG, Condition=CHASSIS(BAD_FAN>=1), Obj:Chassis [ BAD_FAN,1] has contributed to switch status MARGINAL.
2024/09/18-12:51:23, [MAPS-1020], 331, FID 128, WARNING, BrocadeG720, Switch wide status has changed from HEALTHY to CRITICAL.
2024/09/18-12:56:35, [HIL-1517], 332, CHASSIS, WARNING, BrocadeG720, Fan speed of all the fan FRUs changing to 17400 RPM as per environmental specifications.
2024/09/18-12:56:36, [EM-1037], 333, CHASSIS, INFO, BrocadeG720, Fan 2 is Ok.
2024/09/18-12:56:36, [EM-1037], 335, CHASSIS, INFO, BrocadeG720, PS 2 is Ok.
2024/09/18-12:57:23, [MAPS-1020], 336, FID 128, WARNING, BrocadeG720, Switch wide status has changed from CRITICAL to HEALTHY.
2024/09/18-13:11:48, [HIL-1517], 337, CHASSIS, WARNING, BrocadeG720, Fan speed of all the fan FRUs changing to 12200 RPM as per environmental specification

 

  • Check for Loose power feed to the PSU. 
  • If power feed looks fine, then proceed to the solution.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.