Skip to main content
NetApp Knowledge Base

Brocade switch port offline and in “No light” state with Rx power low/-inf due to faulty end device hardware

Views:
1,089
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

Applies to

Brocade Switch

Issue

  • Switch port flapped and state shows as No_light under switchshow output:

Index Port Address Media Speed  State    Proto
==============================================
 ----- Truncated -----
   5   5   010500   id     4G   No_Light    FC  

  • Portshow of the affected port reports offline status:

portshow 5
portDisableReason: None
portCFlags: 0x0
portFlags: 0x21     PRESENT U_PORT DISABLED
LocalSwcFlags: 0x0
portType:  26.0
portState: 2    Offline  
Protocol: FC
portPhys:  4    No_Light     portScn:   2    Offline   
port generation number:    748
state transition count:    11      

  • sfpshow reports Rx value is too low

Slot  5/Port 21:
=============
Identifier:  3    SFP
Connector:   7    LC
Transceiver: 6804404000000000 8,16,32_Gbps M5 sw Short_dist
[...]
Vendor Name: BROCADE
Vendor OUI:  00:05:1e
Vendor PN:   57-1000333-01
Vendor Rev:  A
[...]
Temperature: 59      Centigrade
Current:     7.640   mAmps
Voltage:     3327.1  mVolts
RX Power:    -25.1   dBm (3.1  uW)
TX Power:    -1.3    dBm (743.9 uW)

  • sfpshow reports Rx to be -inf

=============
Slot  4/Port  6:
=============
Identifier:  3    SFP
Connector:   7    LC
Transceiver: 6804406000000000 8,16,32_Gbps M5 sw Inter,Short_dist
..
Vendor Name: BROCADE
Vendor OUI:  00:05:1e
Vendor PN:   57-1000485-01
Vendor Rev:  B
Wavelength:  850  (units nm)
...
O-Wrap Control: 0
..
Current:     7.496   mAmps
Voltage:     3274.5  mVolts
RX Power:    -inf    dBm (0.0  uW)
TX Power:    -1.0    dBm (798.8 uW)

  • porterrshow reported linkfail, loss sig and pcs error

/fabos/cliexec/porterrshow :
          frames        enc     crc     crc     too     too     bad     enc    disc    link    loss    loss    frjt    fbsy     c3timeout     pcs      uncor
        tx       rx      in     err     g_eof   shrt    long    eof     out    c3      fail    sync    sig                      tx      rx      err     err
  22:    5.1g    1.2g    0       0       0       0       0       0       0       0      12       0      16       0       0       0       0      21       3

  • LR_OUT error reported in  sshow_fabric logs:

23:32:24.171xx4 SCN AC_PORT g=0xxc8 LR_OUT                  A2,P2  A2,P3  22    NA
23:32:24.17xx48 *Snd port state: P3                         A2,P3  A2,P3  22    NA
23:32:24.25xx29 *Snd port state: P0                         A2,P0  A2,P0  22    NA

  • Cable check and SFP replaced on the switch, issue still persists
  • The switch may log the following error in errdump as well
    2024/06/24-10:13:18 (IST), [MAPS-1003], 754746, SLOT 1 | FID 128 | PORT 9/19, WARNING, NTTC_X6_108_FAB2, slot9 port19-H.LIN.HBCNBMOBPJS1.10.227.204.78.JZ6KPT3.HBCNBMOBPJ, U-Port 9/19, Condition=ALL_PORTS(LOSS_SIGNAL/min>3), Current Value:[LOSS_SIGNAL, 19 LOS], RuleName=defALL_PORTSLOSS_SIGNAL_3, Dashboard Category=Port Health, Quiet Time=None. 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.