Issue

  • Switch port shows No_light under switchshow output for F port or ISL port:

Index Port Address Media Speed  State    Proto
==============================================
   5   5   0xx500   id     4G   No_Light    FC Disabled  

  • porterrshow indicates link fail and loss sig errors

/fabos/cliexec/porterrshow :
          frames        enc     crc     crc     too     too     bad     enc    disc    link    loss    loss    frjt    fbsy     c3timeout     pcs      uncor
        tx       rx      in     err     g_eof   shrt    long    eof     out    c3      fail    sync    sig                      tx      rx      err     err
  65:    5.4g    9.4g    0       0       0       0       0       0       0       0       1       0       1       0       0       0       0       0       0

  • Portshow of the affected port reports offline status:

portshow 5
portDisableReason: None
portCFlags: 0x0
portFlags: 0x21     PRESENT U_PORT DISABLED
LocalSwcFlags: 0x0
portType:  26.0
portState: 2    Offline  
Protocol: FC
portPhys:  4    No_Light     portScn:   2    Offline   
port generation number:    748
state transition count:    11      

  • sfpshow reports Rx stat as -inf.

Slot  3/Port 42:
=============
Identifier:  3    SFP
Connector:   7    LC
[...]
Vendor Name: BROCADE
Vendor OUI:  00:05:1e
Vendor PN:   57-1000333-01
Vendor Rev:  A
[...]
Temperature: 53      Centigrade
Current:     7.496   mAmps
Voltage:     3312.0  mVolts
RX Power:    -inf    dBm (0.0  uW)
TX Power:    -0.3    dBm (924.1 uW)

  • sfpshow reports Tx stats as -inf.

Slot  9/Port  1:
=============
Identifier:  3    SFP
Connector:   7    LC
[...]
Vendor Name: BROCADE
Vendor OUI:  00:05:1e
Vendor PN:   57-1000333-01
Vendor Rev:  A
[..]
Temperature: 43      Centigrade
Current:     0.000   mAmps
Voltage:     3313.0  mVolts
RX Power:    -0.6    dBm (880.7uW)
TX Power:    -inf    dBm (0.0   uW)

  • fabriclog indicates that port flapped and went offline

Switch 0; Wed Aug 16 12:15:31 2023 GMT (GMT+0:00)
12:15:31.681477 SCN LR_PORT(0);g=0x0                        D2,P0  D2,P0  27    NA    
12:15:31.695830 SCN Port Online; g=0x0,isolated=0           D2,P0  D2,P1  27    NA    
12:15:31.696439 Port Elp engaged                            D2,P1  D2,P0  27    NA    
12:15:31.696468 *Removing all nodes from port               D2,P0  D2,P0  27    NA    
12:15:31.696612 SCN Port F_PORT                             D2,P1  D2,P0  27    NA    
12:15:53.257221 SCN Port Offline;rsn=0x1,g=0x4a             D2,P0  D2,P0  27    NA    
12:15:53.257228 *Removing all nodes from port               D2,P0  D2,P0  27    NA    

  • Portshow shows  invalid crc threshold
    portshow 3
    portDisableReason: Port Decommissioned, Invalid CRC threshold exceeded
    portCFlags: 0x0
    portFlags: 0x4021 PRESENT U_PORT DISABLED LED LocalSwcFlags: 0x0 portType: 26.0
    portState: Persistently Disabled Protocol: FC
    portPhys: 5 No_Sync
    portScn: 2 Offline port generation number: 82 state transition count: 82"
  • Flapping is observed on both switches for ISL ports.
  • For ISL port end device switch Rx and Tx values can be verified for fault isolation.
  • Errdump on the switch may log the following:  2024/11/16-12:18:16 (IST), [PORT-1003], 126304, FID 128 | PORT 0/31, WARNING, Switch2, Port 31 Faulted because of many Link Failures. 

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.