Brocade switch port flaps due to faulty switch end sfp
Applies to
- All Brocade switch hardware platforms
 - All Brocade Fabric Operating System (FOS) firmware levels
 - Backend MCC switch
 
Issue
- Switch port status shows as "
online" underswitchshow: 
/fabos/bin/switchshow :
Index Slot Port Address Media  Speed        State    Proto
============================================================
75    9   11   0f4b40   id    N32   Online      FC  F-Port  10:00:94:40:c9:cf:4a:b1
C3 discards, C3timeout TX errors, link fail, loss syncanduncorrerrors are reported underporterrshow:
porterrshow 9/11
           frames      enc    crc    crc    too    too    bad    enc   disc   link   loss   loss   frjt   fbsy  c3timeout    pcs    uncor
        tx     rx      in    err    g_eof  shrt   long   eof     out   c3    fail    sync   sig                  tx    rx     err    err
75:  204.0m 293.1m   0      0      0      0      0      0      0    540      447      284      1      0      0    5400      0      0      96
Switchshowoutput shows the port in "In_Sync" state -
Index Slot Port Address Media Speed State Proto 
============================================================ 
74 9 10 674a40 id N16 In_Sync FC
- Low Tx power reported on the Brocade switch port under 
sfpshowoutput. 
=============
Port  4:
=============
Length 62.5u:   0    (units 10 meters)
Length Cu:   0    (units 1 meter)
Vendor Name: BROCADE
Vendor OUI:  00:05:1e
Vendor PN:   57-0000088-01
Vendor Rev:  A
Wavelength:  850  (units nm)
Options:     003a Loss_of_Sig,Tx_Fault,Tx_Disable
BR Max:      0
BR Min:      0
Serial No:   HAF618230000T4B
RX Power:    -3.0    dBm (501.1uW)
TX Power:    -7.1    dBm (195.8 uW)
 
- Link resets(
LR_OUT) reported underFabriclogoutput andoffline,onlineevents being reported 
Switch 0; Fri Nov 11 11:23:12 2022 IST (GMT+5:30)
22:52:28.290358 SCN LR_PORT(0);g=0x19ee LR_OUT              A2,P0  A2,P0  75    NA    
23:08:39.902472 SCN LR_PORT(0);g=0x19ee LR_OUT              A2,P0  A2,P0  75    NA    
23:17:38.738930 SCN LR_PORT(0);g=0x19ee LR_OUT              A2,P0  A2,P0  75    NA    
23:22:26.529633 SCN LR_PORT(0);g=0x19ee LR_OUT              A2,P0  A2,P0  75    NA    
23:24:29.226184 SCN LR_PORT(0);g=0x19ee LR_OUT              A2,P0  A2,P0  75    NA    
23:25:11.419546 SCN LR_PORT(0);g=0x19ee LR_OUT              A2,P0  A2,P0  75    NA    
23:25:53.721693 SCN LR_PORT(0);g=0x19ee LR_OUT              A2,P0  A2,P0  75    NA
15:43:33.967361 SCN Port Offline;rsn=0x2,g=0x2e50           A2,P0  A2,P0  78    NA    
15:43:33.967370 *Removing all nodes from port               A2,P0  A2,P0  78    NA    
15:43:34.615134 SCN LR_PORT(0);g=0x2e50                     A2,P0  A2,P0  78    NA    
15:43:34.694264 SCN Port Online; g=0x2e50,isolated=0        A2,P0  A2,P1  78    NA    
15:43:34.695063 Port Elp engaged                            A2,P1  A2,P0  78    NA    
15:43:34.695079 *Removing all nodes from port               A2,P0  A2,P0  78    NA    
15:43:34.695304 SCN Port F_PORT                             A2,P1  A2,P0  78    NA    
15:51:04.900869 SCN Port Offline;rsn=0x4,g=0x2e52           A2,P0  A2,P0  78    NA    
15:51:04.900878 *Removing all nodes from port               A2,P0  A2,P0  78    NA    
15:51:04.913521 SCN LR_PORT(0);g=0x2e52                     A2,P0  A2,P0  78    NA    
15:51:04.986758 SCN Port Online; g=0x2e52,isolated=0        A2,P0  A2,P1  78    NA    
15:51:04.986848 Port Elp engaged                            A2,P1  A2,P0  78    NA    
15:51:04.986862 *Removing all nodes from port               A2,P0  A2,P0  78    NA    
15:51:04.987210 SCN Port F_PORT                             A2,P1  A2,P0  78    NA  
Sfpshowindicates that Rx & Tx are in optimal range.
Slot  9/Port 11:
=============
RX Power:    -2.4    dBm (573.4uW)
TX Power:    -1.0    dBm (795.1 uW)
- In 
errdumplogs RuledefALL_TARGET_PORTSSTATE_CHG_3along withdefRD_1stDATA_TIME_11000&defRD_STATUS_TIME_12000rules generated which indicates that port state is changing more then 3 times per min. 
2023/01/28-16:03:41, [MAPS-1003], 187624, SLOT 1 | FID 128, WARNING, Switch_Name, slot9 port14, F-Port 9/14, Condition=ALL_TARGET_PORTS(STATE_CHG/min>3), Current Value:[STATE_CHG, 4], RuleName=defALL_TARGET_PORTSSTATE_CHG_3, Dashboard Category=Port Health.2023/04/24-19:37:30 (IST), [MAPS-1003], 193109, SLOT 2 | FID 128, WARNING, Switch_Name, Flow (SID=0x665641,DID=0x663440,Host Port=10/6), Condition=sys_flow_monitor_scsi(RD_1stDATA_TIME/10SEC>11000), Current Value:[RD_1stDATA_TIME, 12952 Microseconds], RuleName=defRD_1stDATA_TIME_11000, Dashboard Category=IO Latency, Quiet Time=10 min.
2023/01/28-16:04:05, [MAPS-1003], 187625, SLOT 1 | FID 128, WARNING, Switch_Name, slot9 port14, F-Port 9/14, Condition=ALL_OTHER_F_PORTS(STATE_CHG/min>5), Current Value:[STATE_CHG, 6], RuleName=defALL_OTHER_F_PORTSSTATE_CHG_5, Dashboard Category=Port Healt
2023/01/28-16:04:53, [MAPS-1003], 187626, SLOT 1 | FID 128, WARNING, Switch_Name, slot9 port14, F-Port 9/14, Condition=ALL_TARGET_PORTS(STATE_CHG/min>3), Current Value:[STATE_CHG, 4], RuleName=defALL_TARGET_PORTSSTATE_CHG_3, Dashboard Category=Port Health.
2023/04/24-19:37:30 (IST), [MAPS-1003], 193110, SLOT 2 | FID 128, WARNING, Switch_Name, Flow (SID=0x665641,DID=0x663440,Host Port=10/6), Condition=sys_flow_monitor_scsi(RD_STATUS_TIME/10SEC>12000), Current Value:[RD_STATUS_TIME, 12953 Microseconds], RuleName=defRD_STATUS_TIME_12000, Dashboard Category=IO Latency, Quiet Time=10 min.
Frame timeoutevents reported in theerrdumplog on the switch end, stating which port received a frame (rx) and where it cannot be transmitted on (tx) along withlink resetevents:
2024/02/25-02:26:06 (GMT), [AN-1014], 588, FID 128, INFO, switch, Frame timeout detected, tx port 4 rx port 20, sid 500xx, did 704zz, timestamp 2024-02-25 02:26:06 .
2024/02/25-02:26:07 (GMT), [AN-1014], 608, FID 128, INFO, switch, Frame timeout detected, tx port 4 rx port 0, sid 700xx, did 704zz, timestamp 2024-02-25 02:26:07 .
2024/02/25-02:26:08 (GMT), [C4-1014], 628, CHASSIS | PORT 0/4, WARNING, switch,  Link Reset on Port S0,P4(22) vc_no=0 crd(s)lost=6 auto trigger.