Issue

  • Link resets reported under Fabriclog output as shown below:

Switch 0; Mon Dec 12 23:02:33 2022 IST (GMT+5:30)
23:02:33.251899 SCN Port Offline;rsn=0x3,g=0x4574           A2,P0  A2,P0  141   NA
23:02:33.251907 *Removing all nodes from port               A2,P0  A2,P0  141   NA

23:02:34.716692 SCN LR_PORT(0);g=0x4574                     A2,P0  A2,P0  141   NA
23:02:34.776188 SCN Port Online; g=0x4574,isolated=0        A2,P0  A2,P1  141   NA
23:02:34.777511 Port Elp engaged                            A2,P1  A2,P0  141   NA
23:02:34.777531 *Removing all nodes from port               A2,P0  A2,P0  141   NA
23:02:34.777762 SCN Port F_PORT                             A2,P1  A2,P0  141   NA
23:02:37.875677 SCN Port Offline;rsn=0x3,g=0x4576           A2,P0  A2,P0  141   NA
23:02:37.875685 *Removing all nodes from port               A2,P0  A2,P0  141   NA
23:02:39.656807 SCN LR_PORT(0);g=0x4576                     A2,P0  A2,P0  141   NA
23:02:39.731303 SCN Port Online; g=0x4576,isolated=0        A2,P0  A2,P1  141   NA
23:02:39.733589 Port Elp engaged                            A2,P1  A2,P0  141   NA
23:02:39.733610 *Removing all nodes from port               A2,P0  A2,P0  141   NA
23:02:39.733843 SCN Port F_PORT                             A2,P1  A2,P0  141   NA

 

  • Switch port status shows as "online" under switchshow:
/fabos/bin/switchshow :
switchName:  XXXX
switchType:  166.0
switchState: Online
LS Attributes:      [FID: 128, Base Switch: No, Default Switch: Yes, Ficon Switch: No, Address Mode 0]
Index Slot Port Address Media  Speed        State    Proto
============================================================
141    3   29   668d40   id    N8        Online      FC  F-Port  21:00:00:24:ff:yy:xx:xx
  • Link reset seen under Fabriclog on switch-

15:38:51.649933 SCN LR_PORT(0);g=0x9fe LR_IN                A2,P0  A2,P0  118   NA
16:16:45.053105 SCN LR_PORT(0);g=0x9fe LR_IN                A2,P0  A2,P0  118   NA
16:34:18.013690 SCN LR_PORT(0);g=0x9fe LR_IN                A2,P0  A2,P0  118   NA

 

  • Errdump reports link reset and frame timeout on the port-

2024/07/11-09:09:57 (IST), [C4-1014], 2442642, SLOT 1 | CHASSIS | PORT 12/6, WARNING, switch,  Link Reset on Port S12,P118(63) vc_no=0 crd(s)lost=0 auto trigger.
2024/07/11-09:09:57 (IST), [C4-1014], 2442642, SLOT 1 | CHASSIS | PORT 12/6, WARNING, switch,  Link Reset on Port S12,P118(63) vc_no=0 crd(s)lost=0 auto trigger.
2024/07/11-09:38:43 (IST), [AN-1014], 2443024, SLOT 1 | FID 128, INFO, switch, Frame timeout detected, tx port 12/6 rx port 12/29, sid 6b52xx, did 6b76xx, timestamp

 

  • Enc_out errors are reported under porterrshow:

/fabos/cliexec/porterrshow :
          frames        enc     crc     crc     too     too     bad     enc    disc    link    loss    loss    frjt    fbsy     c3timeout     pcs      uncor
        tx       rx      in     err     g_eof   shrt    long    eof     out    c3      fail    sync    sig                      tx      rx      err     err
141:  168     929       0       0       0       0       0       0       6.9k    0       0       0       0       0       0       0       0       0       0

 

  • crc err and crc g_eof along with c3 tx discards reported under porterrshow-

        frames        enc     crc     crc     too     too     bad     enc    disc    link    loss    loss    frjt    fbsy     c3timeout     pcs      uncor
      tx        rx     in     err     g_eof   shrt    long    eof     out    c3      fail    sync    sig                      tx      rx      err     err
118:    5.2g    5.8g    0      5.2k    4.8k   14       0     408       0       2.2k    0       0       0       0       0       2.2k    0     559.2k    0

 

  • Portshow reports high Invalid Transmitted Words (ITW) counter s reported

portshow 141
portDisableReason: None
portCFlags: 0x1
portFlags: 0x20b03  PRESENT ACTIVE F_PORT G_PORT U_PORT LOGICAL_ONLINE LOGIN NOELP ACCEPT FLOGI
LocalSwcFlags: 0x0
portType:  26.0
portState: 1 Online
Protocol: FC
portPhys:  6 In_Sync      portScn:   32 F_Port
port generation number:    17782
state transition count:    24

portId:    668d40
portIfId:    43320035
portWwn:   XX:8d:88:94:71:a2:XX.XX
portWwn of device(s) connected:
       XX:00:00:24:ff:1d:xy:xx
Distance:  normal
portSpeed: N8Gbps


Interrupts:        0       Link_failure: 0     Frjt:         0
Unknown:           0       Loss_of_sync: 0     Fbsy:         0
Lli:               0       Loss_of_sig:  0
Proc_rqrd:         0       Protocol_err: 0
Timed_out:         0       Invalid_word: 7186
Tx_unavail:        0       Invalid_crc:  0
Delim_err:         0       Address_err:  0
Lr_in:             0       Ols_in:       0
Lr_out:            0       Ols_out:      0
Cong_Prim_in:       0

 

  • Errdump reports RuleName=defALL_HOST_PORTSITW_21 getting trggered due to these ITW errors reporte din huge number.

    Errdump:
    2022/12/12-19:20:16, [MAPS-1003], 769558, SLOT 2 | FID 128, WARNING, switchXX, slot3 port29-Host.LINUX:CBXPR_APP02.ALIAS:HBCBXPRDAP02_HBA2:VSP5, F-Port 3/29, Condition=ALL_HOST_PORTS(ITW/min>21), Current Value:[ITW, 521 ITWs], RuleName=defALL_HOST_PORTSITW_21, Dashboard Category=Port Health.
     2022/12/12-19:21:16, [MAPS-1003], 769561, SLOT 2 | FID 128, WARNING, switchXX, slot3 port29-Host.LINUX:CBXPR_APP02.ALIAS:HBCBXPRDAP02_HBA2:VSP5, F-Port 3/29, Condition=ALL_HOST_PORTS(ITW/min>21), Current Value:[ITW, 824 ITWs], RuleName=defALL_HOST_PORTSITW_21, Dashboard Category=Port Health.
     2022/12/12-19:22:16, [MAPS-1003], 769562, SLOT 2 | FID 128, WARNING, switchXX, slot3 port29-Host.LINUX:CBXPR_APP02.ALIAS:HBCBXPRDAP02_HBA2:VSP5, F-Port 3/29, Condition=ALL_HOST_PORTS(ITW/min>21), Current Value:[ITW, 1422 ITWs], RuleName=defALL_HOST_PORTSITW_21, Dashboard Category=Port Health.

 

  • Sfpshow reports low Rx power

sfpshow:
=============
Slot  3/Port 29:
=============
Identifier:  3    SFP
Connector:   7    LC
Transceiver: 6804406000000000 8,16,32_Gbps M5 sw Inter,Short_dist
Encoding:    6    64B66B
Baud Rate:   280  (units 100 megabaud)
Length 9u:   0    (units km)
Length 9u:   0    (units 100 meters)
Length 50u (OM2):  2    (units 10 meters)
Length 50u (OM3):  7    (units 10 meters)
Length 62.5u:0    (units 10 meters)
Length 50u (OM4):  10   (units 10 meters)
Vendor Name: BROCADE
Vendor OUI:  00:05:1e
Vendor PN:   57-1000333-01
Alarm flags[0,1] = 0x0, 0x0
Warn Flags[0,1] = 0x0, 0x0
Temperature: 52      Centigrade
Current:     5.832   mAmps
Voltage:     3322.6  mVolts
RX Power:    -8.8    dBm (130.5uW)
TX Power:    -1.3    dBm (743.3 uW)

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.