Brocade X7-8 core blade shows faulty due to bad control processor blade
Applies to
Brocade X7-8
Issue
- Core blade in slot 8 is faulty:
admin> slotshowSlot Blade Type ID Status-----------------------------------1 CP BLADE 220 ENABLED2 CP BLADE 220 ENABLED3 SW BLADE 216 ENABLED4 SW BLADE 216 ENABLED5 SW BLADE 216 ENABLED6 SW BLADE 216 ENABLED7 CORE BLADE 215 ENABLED8 CORE BLADE 215 FAULTY (142)9 SW BLADE 216 ENABLED10 UNKNOWN VACANT11 UNKNOWN VACANT12 UNKNOWN VACANT- This happened when control processor in slot 1 reset:
[EM-1051], 87845, SLOT 2 | CHASSIS, INFO, fcfb04, Slot 8: Inconsistency detected, FRU reinitialized.[EM-1033], 87857, SLOT 2 | CHASSIS, ERROR, fcfb04, CP in Slot 1 set to faulty because CP ERROR asserted.[EM-1047], 87858, SLOT 2 | CHASSIS, INFO, fcfb04, CP in slot 1 not faulty, CP ERROR deasserted.[EM-1134], 87860, SLOT 2 | FFDC | CHASSIS, ERROR, fcfb04, Slot 8 set to faulty, rc=2008e.[HAM-1004], 87863, SLOT 1 | CHASSIS, INFO, fcfb04, Processor rebooted - Software Fault:ASSERTslotpoweroff/slotpoweronof faulty core blade was performed without success- Reseat of core blade was performed without success
- Core blade was replaced without success