Skip to main content
NetApp Knowledge Base

Brocade X6-8 director does not come online after a power outage

Views:
280
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

Applies to

  • FC
  • SAN
  • Brocade X6-8
  • Brocade Fabric Operating System (FOS)

Issue

  • The switch is offline/disabled:

switchshow        :
switchName:     switch
switchType:     166.0
switchState:    Offline
switchMode:     Native
switchRole:     Disabled

  • Both core blades are booting or showing as faulty, other blades may also be down:
slotshow -m       :
 
Slot   Blade Type     ID    Model Name     Status
--------------------------------------------------
  1     CP BLADE    175     CPX6           ENABLED
  2     CP BLADE    175     CPX6           ENABLED
  3     UNKNOWN                            VACANT
  4     SW BLADE    178     FC32-48        INSERTED, NOT POWERED ON
  5     SW BLADE    178     FC32-48        INSERTED, NOT POWERED ON
  6     SW BLADE    178     FC32-48        ENABLED
  7     CORE BLADE  177     CR32-8         FAULTY (21)
  8     CORE BLADE  177     CR32-8         DIAG RUNNING POST2
  9     SW BLADE    178     FC32-48        ENABLED
10     SW BLADE    178     FC32-48        ENABLED
11     UNKNOWN                            VACANT
12     UNKNOWN                            VACANT
  • Reseating individual blades, or both core blades at once, does not bring the blades back up.
  • Power cycling blades with slotPowerOff and slotPowerOn does not bring the blades back up.
  • Rebooting the switch does not bring the blades back up.
  • errdump shows both core blades in slot 7 and 8 failing to boot:
2023/11/02-11:15:32, [BL-1017], 1157, SLOT 2 | CHASSIS, INFO, X6-8, Slot 7 Initializing...
2023/11/02-11:15:52, [BL-1019], 1158, SLOT 2 | CHASSIS, INFO, X6-8, Slot 7, retry 1, internal port retry initialization, ports: 220 .
2023/11/02-11:16:02, [BL-1019], 1159, SLOT 2 | CHASSIS, INFO, X6-8, Slot 7, retry 2, internal port retry initialization, ports: 217 220 .
2023/11/02-11:16:12, [BL-1002], 1160, SLOT 2 | FFDC | CHASSIS, CRITICAL, X6-8, Init Failed: slot 7 DISABLED because internal ports were not ONLINE, ports: 217 220 .
2023/11/02-11:16:12, [RAS-1002], 1161, SLOT 2 | CHASSIS, WARNING, X6-8, First failure data capture (FFDC) reached maximum storage size (15 MB).
2023/11/02-11:16:13, [EM-1134], 1162, SLOT 2 | FFDC | CHASSIS, ERROR, X6-8, Slot 7 set to faulty, rc=20015.
2023/11/02-11:21:54, [EM-2003], 1165, SLOT 2 | CHASSIS, ERROR, X6-8, Slot 8 has failed the POST tests. FRU is being faulted.
2023/11/02-11:21:54, [EM-1072], 1166, SLOT 2 | FFDC | CHASSIS, CRITICAL, X6-8, Chassis cannot become ready since no Core Blades are available.
  • errdump shows switch auto-reboots and reports it is not ready:
2023/11/02-11:29:37, [SWCH-1001], 1187, SLOT 2 | FID 128, ERROR, switch, Switch is not in ready state - Switch enable failed, switch status= 0x4, c_flags = 0x10400.
2023/11/02-11:35:39, [HAM-1007], 1188, SLOT 2 | FFDC | CHASSIS, CRITICAL, X6-8, Need to reboot the system for recovery, reason: Software Bootup Failure:Bringup timed out.
2023/11/02-11:36:09, [HAM-1008], 1189, SLOT 2 | FFDC | CHASSIS, CRITICAL, X6-8, Rebooting the system for recovery - auto-reboot is enabled.
  • hadump shows CP blades are not in sync:
Local CP (Slot 2, CP1): Active, Cold Recovered
Remote CP (Slot 1, CP0): Standby, Healthy
HA enabled, Heartbeat Up, HA State not in sync

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.