Skip to main content
NetApp Knowledge Base

Brocade G series switch reporting faulty FAN

Views:
1,476
Visibility:
Public
Votes:
4
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

Applies to

  • Brocade G610
  • Metrocluster Brocade G610 switch
  • Brocade G720
  • Metrocluster Brocade G720 switch

Issue

  • Fan of Brocade switch goes to faulty state and auto recovers
  • No environmental issues present
  • In the errdump logs, it appears to have recovered by performing removal and re-insertion, which is not true:
2021/02/11-14:28:02, [HIL-1206], 586, CHASSIS, ERROR, BrocadeG610, Fan 1 sensor 1 , speed (2649 RPM) below threshold.
2021/02/11-14:28:02, [HIL-1312], 587, CHASSIS, WARNING, BrocadeG610, 1 blower(s) failed. Check all blower units immediately.
2021/02/11-14:28:02, [EM-1034], 588, CHASSIS, ERROR, BrocadeG610, Fan 1 set to faulty, rc=20006.
2021/02/11-14:28:14, [MAPS-1021], 589, FID 128, WARNING, brocade-sw1, RuleName=defCHASSISBAD_FAN_MARG, Condition=CHASSIS(BAD_FAN>=1), Obj:Chassis [ BAD_FAN,1] has contributed to switch status MARGINAL.
2021/02/11-14:28:14, [MAPS-1020], 590, FID 128, WARNING, brocade-sw1, Switch wide status has changed from HEALTHY to MARGINAL.
2021/02/11-14:30:01, [EM-1050], 591, CHASSIS, INFO, BrocadeG610, FRU Fan 1 removal detected.
2021/02/11-14:30:01, [EM-1049], 592, CHASSIS, INFO, BrocadeG610, FRU Fan 1 insertion detected.
2021/02/11-14:30:14, [MAPS-1020], 593, FID 128, WARNING, brocade-sw1, Switch wide status has changed from MARGINAL to HEALTHY.
  • fanshow output: 
Fan 1 is Ok, speed is 25641 RPM
Fan 2 is Faulty
 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.