Skip to main content
NetApp Knowledge Base

Brocade G7 reporting faulty FAN alerts in errdump

Views:
50
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:
8/7/2024, 8:03:37 AM

Applies to

  • Brocade G7 switches
  • FOS v9.0.1b

Issue

  • Brocade switch is reporting faulty FAN alerts, and the same MAPS alerts are identified in errdump.

2024/06/26-07:35:09, [MAPS-1021], 304, FID 128, WARNING, SSW-02, RuleName=defCHASSISBAD_FAN_CRIT, Condition=CHASSIS(BAD_FAN>=2), Obj:Chassis [ BAD_FAN,2] has contributed to switch status CRITICAL.
2024/06/26-07:34:13, [MAPS-1021], 6, FID 128, WARNING, SSW-01, RuleName=defCHASSISBAD_PWR_CRIT, Condition=CHASSIS(BAD_PWR>=1), Obj:Chassis [ BAD_PWR,1] has contributed to switch status CRITICAL.

  • fanshow indicates optimal status in logs.

/fabos/cliexec/psshow -v:

Power Supply #1 is OK
Power Supply #2 is OK

/fabos/cliexec/fanshow:
Fan 1 is Ok, speed is 13605 RPM
Fan 2 is Ok, speed is 13333 RPM

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.