Brocade G7 reporting faulty FAN alerts in errdump
Applies to
- Brocade G7 switches
- FOS v9.0.1b
Issue
- Brocade switch is reporting faulty FAN alerts, and the same MAPS alerts are identified in
errdump
.
2024/06/26-07:35:09, [MAPS-1021], 304, FID 128, WARNING, SSW-02, RuleName=defCHASSISBAD_FAN_CRIT, Condition=CHASSIS(BAD_FAN>=2), Obj:Chassis [ BAD_FAN,2] has contributed to switch status CRITICAL.
2024/06/26-07:34:13, [MAPS-1021], 6, FID 128, WARNING, SSW-01, RuleName=defCHASSISBAD_PWR_CRIT, Condition=CHASSIS(BAD_PWR>=1), Obj:Chassis [ BAD_PWR,1] has contributed to switch status CRITICAL.
fanshow
indicates optimal status in logs.
/fabos/cliexec/psshow -v:
Power Supply #1 is OK
Power Supply #2 is OK
/fabos/cliexec/fanshow:
Fan 1 is Ok, speed is 13605 RPM
Fan 2 is Ok, speed is 13333 RPM