Brocade FC switch nondisruptive upgrade path had a disruptive reboot
Applies to
- Brocade G620
- Fabric OS (FOS) v9.1.1a
Issue
- Device attached to Brocade switch sees link break/port offline during an upgrade that is expected to be nondisruptive, example ONTAP EMS logs:
Link break detected on Fibre Channel target HBA 2a with event status 1 , topology type 1, status1 0x0, status2 0x0.
errdumpallfromsupportsavelogs shows a port lost sync during the upgrade:
[C4-5257], 91/0, CHASSIS | PORT 0/4, WARNING, BrocadeG620, S0,P4(63): (PHY05): HA recovery check failure - port lost sync C4_LLIS_LOSYNC, lli_status = 0x08174004, OID:0x4302803f, SPOID:0x43068104, c4_physm.c, line: 1178, comp:insmod
- Port errors seen:
/fabos/cliexec/porterrshow :
frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs uncor
tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err err
4: 12.8g 61.8g 0 0 0 0 0 0 0 11.1k 0 0 0 0 0 11.1k 0 0 3