Issue

  • A Brocade fiber channel port connecting to an end device (host, storage, ATTO, etc) switched from a normal state to an No_module state

SWITCHCMD /fabos/bin/switchshow:
Index Slot Port Address Media Speed State Proto
============================================================
120 4 24 667800 -- N32 No_Module FC

  • Sfpshow indicated that Media is not installed for that specific port

=============
Slot 4/Port 24:
=============
Media not installed
Extended smart data is Not available

  • To isolate the issue below troubleshooting steps can be performed
    • Check if there are any SFP present on that specific port.
    • If sfp is present, reseat the SFP module on that port.
    • If issue persists post reseating, swap it with a known good SFP and verify the port state.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.