Issue

  • The stand-by CP Blade experiences a failure, causing HA to be non-redundant or out of sync.
  • errdump -a output will mark the blade as faulty,  and hashow will confirm that high availability is not operating.

Examples:

Switchname:admin> errdump -a

2020/03/23-14:16:38, [EM-1033], 2226, SLOT 6 | CHASSIS, ERROR, switchname, CP in Slot 7 set to faulty because CP ERROR asserted.

2020/03/23-14:16:53, [EM-1047], 2227, SLOT 6 | CHASSIS, INFO, switchname, CP in slot 7 not faulty, CP ERROR deasserted.

2020/03/23-14:20:03, [EM-1033], 2228, SLOT 6 | CHASSIS, ERROR, switchname, CP in Slot 7 set to faulty because CP ERROR asserted.

2020/03/23-14:20:18, [EM-1047], 2229, SLOT 6 | CHASSIS, INFO, switchname, CP in slot 7 not faulty, CP ERROR deasserted.
2022/07/26-09:18:24, [FSSM-1003], 21471, SLOT 1 | CHASSIS, WARNING, switchname, HA State out of sync.

 

Switchname:admin> hashow   
 Local CP (Slot 6, CP0): Active, Warm Recovered   
 Remote CP (Slot 7, CP1): Non-Redundant   

/fabos/cliexec/hadump:
---------------------------------------
TIME_STAMP: Jul 27 10:16:34.770774
---------------------------------------
Local CP (Slot 1, CP0): Active, Cold Recovered
Remote CP (Slot 2, CP1): Non-Redundant

 

/fabos/cliexec/slotshow -m:

Slot   Blade Type     ID    Model Name     Status 
--------------------------------------------------
  1     CP BLADE    175     CPX6           ENABLED
  2     CP BLADE    175     CPX6           FAULTY (53) - possible RRD
  3     SW BLADE    178     FC32-48        ENABLED
  4     SW BLADE    178     FC32-48        ENABLED
  5     CORE BLADE  176     CR32-4         ENABLED
  6     CORE BLADE  176     CR32-4         ENABLED
  7     UNKNOWN                            VACANT
  8     AP BLADE    186     SX6            ENABLED

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.