Skip to main content
NetApp Knowledge Base

SwitchIfIslDownWarn_Alert reported for BES-53248 cluster switches

Views:
285
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9
  • BES-53248 Cluster switches

Issue

  • The following alert is reported for BES-53248 cluster switch in the event logs:

[Node-01: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: SwitchIfIslDownWarn_Alert[CLUSW01/Slot: 0 Port: 55 100G - Level].

  • The switch health is degraded due to this issue:

Cluster::>  system health subsystem show
Subsystem         Health
----------------- ------------------
SAS-connect       ok
Environment       ok
Memory            ok
Service-Processor ok
Switch-Health     degraded
CIFS-NDO          ok
Motherboard       ok
IO                ok
MetroCluster      ok
MetroCluster_Node ok
FHM-Switch        ok
FHM-Bridge        ok
SAS-connect_Cluster
                  ok
13 entries were displayed.

  • The status of the reported ISL port is down from both cluster switches:

CLUSW01# show port all

                 Admin     Physical   Physical   Link   Link    LACP   Actor
Intf      Type   Mode      Mode       Status     Status Trap    Mode   Timeout
--------- ------ --------- ---------- ---------- ------ ------- ------ --------
0/55      PC Mbr Enable    100G Full             Down   Enable  Enable long
0/56      PC Mbr Enable    100G Full  100G Full  Up     Enable  Enable long

  • There is a cable connected to the ISL port with error:

CLUSW01# show fiber-ports optical-transceiver-info all

                                Link Link                                          Nominal
                              Length Length Link                                  Bit Rate
       Number                   50um 62.5um Length                                Per Lane
Port   of Lanes Vendor Name      [m] [m]     [m]   Serial Number    Part Number     [Mbps]   Rev  Compliance
------ -------- ---------------- --- ----   ------ ---------------- ---------------- -----   ---- ----------------
0/55      4     Molex            0   0      1M     93AXXXXXX0028    112-00573        25500     B0 100GBase-CR4

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.