Issue
- The following alert is reported for BES-53248 cluster switch in the event logs:
[Node-01: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: SwitchIfIslDownWarn_Alert[CLUSW01/Slot: 0 Port: 55 100G - Level].
- The switch health is degraded due to this issue:
Cluster::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor ok
Switch-Health degraded
CIFS-NDO ok
Motherboard ok
IO ok
MetroCluster ok
MetroCluster_Node ok
FHM-Switch ok
FHM-Bridge ok
SAS-connect_Cluster
ok
13 entries were displayed.
- The status of the reported ISL port is down from both cluster switches:
CLUSW01# show port all
Admin Physical Physical Link Link LACP Actor
Intf Type Mode Mode Status Status Trap Mode Timeout
--------- ------ --------- ---------- ---------- ------ ------- ------ --------
0/55 PC Mbr Enable 100G Full Down Enable Enable long
0/56 PC Mbr Enable 100G Full 100G Full Up Enable Enable long
- There is a cable connected to the ISL port with error:
CLUSW01# show fiber-ports optical-transceiver-info all
Link Link Nominal
Length Length Link Bit Rate
Number 50um 62.5um Length Per Lane
Port of Lanes Vendor Name [m] [m] [m] Serial Number Part Number [Mbps] Rev Compliance
------ -------- ---------------- --- ---- ------ ---------------- ---------------- ----- ---- ----------------
0/55 4 Molex 0 0 1M 93AXXXXXX0028 112-00573 25500 B0 100GBase-CR4