MultiRDY and link reset seen on Brocade FC switch port
Applies to
- Brocade Fibre Channel (FC) switch
- FOS v9.x
Issue
- MultiRDY and LinkReset events observed on host-connected switch port on Brocade switch.
2026/08/09-07:31:49 (IST), [C5-1040], 11588, SLOT 1 | CHASSIS | PORT 6/13, WARNING, xx-xxx-xx, Multi RDY/Frame Loss detected on Slot 6, Port xx(1x) m_rdy(0x0)/m_frame(0x1). Link Reset done.
- Physical-layer errors detected such as
CRC,bad EOF,link failure,loss of signal, anduncorrectableerrors.
frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs uncor tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err err 301: 36.0m 19.0m 0 1 0 0 0 1 0 0 1 0 1 0 0 0 0 0 60
- Port flapping and link resets observed in logs
- SFP Rx & Tx values on the port are optimal.
- Clear the stats and monitor for 24hrs to see if errors are increasing