Cluster outage during BES-53248 cluster interconnect switch upgrade
Applies to
- ONTAP 9
- BES-53248 cluster interconnect switch
Issue
- During upgrade of EFOS firmware on BES-53248 switch, after reload on new version, interfaces connected to storage are down:
Admin Physical Physical Link Link LACP ActorIntf Type Mode Mode Status Status Trap Mode Timeout--------- ------ --------- ---------- ---------- ------ ------- ------ --------0/1 Enable 10G Full Down Enable Enable long0/2 Enable 10G Full Down Enable Enable long- If not noticed and second switch upgraded with same issue, cluster has outage with all cluster applications offline (seen via advanced command
cluster ring show). - Aggregates go to
unknownstatus and NAS data (NFS and CIFS) stops being served. - There are no obvious errors in