Brocade switch shows Power Supply is faulty
Applies to
Brocade switches
Issue
- Amber light or no link lights displayed on the switch PSU.
sensorshow
reports PSU2 as "faulty" and Fan 2 as "Unknown".
sensorshow :
sensor 1: (Temperature) is Ok, value is 39 C
sensor 2: (Fan 1 ) is Ok,speed is 6617 RPM
sensor 3: (Fan 2 ) is Unknown
sensor 4: (Power Supply) is Ok
sensor 5: (Power Supply) is Faulty
psshow
reports Power Supply 2 as faulty:
psshow :
Power Supply #1 is OK
Power Supply #2 is faulty
fanshow
reports Fan 2 as Unknown:
fanshow :
Fan 1 is Ok, speed is 6617 RPM
Fan 2 is Unknown
-
As per
errdump
, could see both PS1 ; PS2 and Fan2 going faulty:
2023/06/21-14:13:39, [EM-1034], 88278, CHASSIS, ERROR, Brocade, PS 2 set to faulty, rc=2000e.
2023/06/21-14:13:41, [FW-1010], 88279, FID 128, WARNING, Brocade, Env Power Supply 2, is below low boundary(High=0, Low=1). Current value is 0 (1 OK/0 FAULTY).
2023/06/21-14:13:41, [FW-1424], 88280, FID 128, WARNING, Brocade, Switch status changed from HEALTHY to MARGINAL.
2023/06/21-14:13:41, [FW-1427], 88281, FID 128, WARNING, Brocade, Switch status change contributing factor Power supply: 1 bad.
2023/06/21-14:13:56, [EM-1034], 88293, CHASSIS, ERROR, Brocade, PS 1 set to faulty, rc=2000e.
2023/06/21-14:14:00, [FW-1010], 88294, FID 128, WARNING, Brocade, Env Power Supply 1, is below low boundary(High=0, Low=1). Current value is 0 (1 OK/0 FAULTY).
2023/06/21-14:14:00, [FW-1424], 88295, FID 128, WARNING, Brocade, Switch status changed from HEALTHY to MARGINAL.
2023/06/21-14:14:00, [FW-1427], 88296, FID 128, WARNING, Brocade, Switch status change contributing factor Power supply: 1 bad.
2023/06/21-14:14:00, [EM-1037], 88298, CHASSIS, INFO, Brocade, PS 1 is no longer faulted.
2023/06/21-14:23:40, [HIL-1610], 88315, CHASSIS, WARNING, Brocade, Fan/PS unit 2 not supplying power, fan speeds may not be available. Please ensure that the unit has power and the switch is on.
2023/06/21-14:23:44, [FW-1431], 88316, FID 2, WARNING, Brocade, Switch status change contributing factor Fan: 1 bad.
2023/06/21-14:23:46, [FW-1431], 88317, FID 128, WARNING, Brocade, Switch status change contributing factor Fan: 1 bad
- Below steps followed to further rule out any potential power issues on site such the power outlet, cables etc before replacing the switch PSU:
- Check if power cable is connected properly.
- Try to swap with good known power cable.
- Reseat power cords and PSU of switch.
- Ensure the external power supply operating normally.
Note: For Brocade 6510 switches, the fans are integrated into the power supply unit
CauseFaulty power supply |