Broadcom Ethernet Switch 53248 (BES-53248)

Issue

  • BES-53248 cluster switches not booting into EFOS, after power down.
    • This would be related to a maintenance activity, environmental issue, etc.
  • EFOS option is missing from the boot device. Example

+----------------------------------------------------------------------------+
|*ONIE: Install OS                                                           |
| ONIE: Rescue                                                               |
| ONIE: Uninstall OS                                                         |
| ONIE: Update ONIE                                                          |
| ONIE: Embed ONIE                                                           |
| DIAG: Diagnostic Mode                                                      |
| DIAG: Burn-In Mode                                                         |
|                                                                            |
|                                                                            |
|                                                                            |
|                                                                            |
+----------------------------------------------------------------------------+

  • From the BES switch outputs, there is an issue reported for a low voltage related to the P3V (Real Time Clock battery). Example:

(switch_name)# linuxsh

# ipmitool sel elist
 ...
 123 | 01/01/2025 | 01:01:01 | Voltage Volt_P3V_BAT | Lower Critical going low  | Asserted | Reading 0.54 < Threshold 2.53 Volts

# ipmitool sensor
...
Volt_P3V3_SUS    | 3.308      | Volts      | ok    | na        | 2.975     | na        | na        | 3.623     | na
Volt_P3V_BAT     | 1.793      | Volts      | cr    | na        | 2.528     | na        | na        | 3.616     | na

# ipmitool sdr
...
Volt_P3V3_SUS    | 3.31 Volts        | ok
Volt_P3V_BAT     | 1.79 Volts        | cr

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.