Loss of host-side connection redundancy detected for direct-attached host
Applies to
- NetApp E-Series
- SANtricity OS 11.30 or later
- Direct-attached host
Issue
- Major Event Log
Loss of host-side connection redundancy detectedbeing reported:
Example:
Date/Time: 1/2/21, 1:02:03 AMSequence number: 1234Event type: 9102Event category: ErrorPriority: CriticalEvent needs attention: trueEvent send alert: trueEvent visibility: trueDescription: Loss of host-side connection redundancy detectedEvent specific codes: 0/0/0Component type: HostComponent location: Host HOST1-HBA2Logged by: Controller in bay A- Recovery Guru entry
Host Redundancy Lostbeing reported:
Example:
Failure Entry 1: ALB_HOST_REDUNDANCY_LOST-Recovery Failure Type Code: 475Storage array: UnnamedAffected host: HOST1-HBA2Affected controller: Controller in bay B- The host has two HBAs configured as two separate hosts in E-Series. Each HBA is direct attached to one of the controllers (A or B). This can be verified using the
HOST-TO-VOLUME ASSIGNMENTSsection of thestorage-array-profile logfile or in SANtricity System Manager under Hosts section.