E-Series controller in lockdown state due to in invalid device in alternate controller
- Views:
- 2,234
- Visibility:
- Public
- Votes:
- 3
- Category:
- e-series-systems
- Specialty:
- esg
- Last Updated:
- 11/15/2024, 1:39:41 PM
Applies to
NetApp E-Series
Issue
Controller is locked down with a 7-segment LED code of either OE L0
or 06 L0
on the back of controller.
The codes indicate the controller is locked down due to hardware mismatch.
-> spriSevenSegShow
Code: 0E L0
Condition: This controller is paired with an invalid device in its alternate controller slot. Replace the in correct controller canister device with a matching
value = 162 = 0xa2
The following error messages may be displayed in the boot sequence (console output) and the debug queue logs:
CtrlMismatchErrType: Ctlr board id:0x15, Alt ctlr board id:0x10
CtrlMismatchErrType: MISMATCH - Controller Board ID=0x15, AltID=0x10