A drawer in the tray has become degraded by controller failure
Applies to
- E-series
- Controller shelf only (it does not apply to drawers in expansion shelves)
Issue
- The major event log (MEL) reports A drawer in the shelf has become degraded.
A:9/28/23 6:14:13 AM (06:14:13) 37166 285f A drawer in the shelf has become degraded - Shelf 99, Drawer 5 <--CRITICAL
A:9/28/23 6:14:13 AM (06:14:13) 37165 285f A drawer in the shelf has become degraded - Shelf 99, Drawer 4 <--CRITICAL
A:9/28/23 6:14:13 AM (06:14:13) 37164 285f A drawer in the shelf has become degraded - Shelf 99, Drawer 3 <--CRITICAL
A:9/28/23 6:14:13 AM (06:14:13) 37163 285f A drawer in the shelf has become degraded - Shelf 99, Drawer 2 <--CRITICAL
A:9/28/23 6:14:13 AM (06:14:13) 37162 285f A drawer in the shelf has become degraded - Shelf 99, Drawer 1 <--CRITICAL
A:9/28/23 6:13:42 AM (06:13:42) 37161 282b Drive shelf path redundancy lost - Shelf 99 <--CRITICAL
State-capture-data>ionShow99>luall 0reports missing path (yellow section is empty):
00010101 t99,s2 SASdr :+++ : + + : 16 0 0 14522 0 : 0 00010102 t99,s3 SASdr :+++ : + * : 16 0 0 10402 0 : 0 00010103 t99,s4 SASdr :+++ : * + : 16 0 0 6042 0 : 0
- MEL also reports Controller removed:
A:9/28/23 6:13:09 AM (06:13:09) 37158 2500 Controller removed - Shelf 99, Bay B <--CRITICAL - The affected controller is not removed manually, but it is unresponsive.