iSCSI connections are lost on some hosts after E-Series controller replacement
- Views:
- 28
- Visibility:
- Public
- Votes:
- 0
- Category:
- e-series-systems
- Specialty:
- esg
- Last Updated:
- 1/27/2025, 4:13:16 AM
Applies to
- E-Series
- SANtricity OS
- Linux DM-MP (Device Mapper Multipath)
- Controller replacement was performed
Issue
- Some hosts loose iSCSI connection(s) after replacement of E-Series controller
- Recovery Guru and
MAJOR-EVENT-LOG
(MEL) reports the following errors:Loss of host-side connection redundancy detected
Volume not on preferred path due to AVT/RDAC failover
ALB_HOST_REDUNDANCY_LOST
NON_PREFERRED_PATH
- Redistribute volumes temporary resolves these errors but they are detected again after several minutes
- No configuration changes performed both on controller and host other than the controller replacement
STATE-CAPTURE-DATA
>spmShow
indicates that the replaced controller does not have iSCSI connections from some hosts that the partner controller has
Example of after the replacement of controller A:
Executing spmShow(0,0,0,0,0,0,0,0,0,0) on controller A:
---I-T-Nexus (PORT) Objects (ITN)---
ITNID InitiatorPort TargetPort Online
----- ------------------------------ ------------------------------ ------
x0005 Host_0000000000000003 iSCSI_TargetPortPR_Ah_ch7 on <IQN>:<HOST1>
x0006 Host_0000000000000004 iSCSI_TargetPortPR_Ah_ch8 on <IQN>:<HOST1>
Executing spmShow(0,0,0,0,0,0,0,0,0,0) on controller B:
---I-T-Nexus (PORT) Objects (ITN)---
ITNID InitiatorPort TargetPort Online
----- ------------------------------ ------------------------------ ------
x0005 Host_0000000100000004 iSCSI_TargetPortPR_Bh_ch8 off <IQN>:<HOST1>
x0006 Host_0000000100000002 iSCSI_TargetPortPR_Bh_ch8 on <IQN>:<HOST1>
x0007 Host_0000000100000002 iSCSI_TargetPortPR_Bh_ch8 on <IQN>:<HOST1>
x0008 Host_0000000100000020 iSCSI_TargetPortPR_Bh_ch8 off <IQN>:<HOST2>
x0009 Host_0000000100000001 iSCSI_TargetPortPR_Bh_ch7 on <IQN>:<HOST2>
x000a Host_000000010000001f iSCSI_TargetPortPR_Bh_ch7 off <IQN>:<HOST1>
x000b Host_0000000100000002 iSCSI_TargetPortPR_Bh_ch8 off <IQN>:<HOST2>
x000c Host_0000000100000001 iSCSI_TargetPortPR_Bh_ch7 on <IQN>:<HOST2>
x000d Host_0000000100000002 iSCSI_TargetPortPR_Bh_ch8 on <IQN>:<HOST3>
x000e Host_0000000100000002 iSCSI_TargetPortPR_Bh_ch8 on <IQN>:<HOST3>