Applies to

  • E-Series
  • SANtricity OS
  • Linux DM-MP (Device Mapper Multipath)
  • Controller replacement was performed

Issue

  • Some hosts loose iSCSI connection(s) after replacement of E-Series controller
  • Recovery Guru and MAJOR-EVENT-LOG (MEL) reports the following errors:
    • Loss of host-side connection redundancy detected
    • Volume not on preferred path due to AVT/RDAC failover
    • ALB_HOST_REDUNDANCY_LOST
    • NON_PREFERRED_PATH
  • Redistribute volumes temporary resolves these errors but they are detected again after several minutes
  • No configuration changes performed both on controller and host other than the controller replacement
  • STATE-CAPTURE-DATA > spmShow indicates that the replaced controller does not have iSCSI connections from some hosts that the partner controller has

Example of after the replacement of controller A:

Executing spmShow(0,0,0,0,0,0,0,0,0,0) on controller A:

---I-T-Nexus (PORT) Objects (ITN)---
ITNID InitiatorPort                  TargetPort                     Online
----- ------------------------------ ------------------------------ ------
x0005 Host_0000000000000003          iSCSI_TargetPortPR_Ah_ch7      on     <IQN>:<HOST1>
x0006 Host_0000000000000004          iSCSI_TargetPortPR_Ah_ch8      on     <IQN>:<HOST1>


Executing spmShow(0,0,0,0,0,0,0,0,0,0) on controller B:

---I-T-Nexus (PORT) Objects (ITN)---
ITNID InitiatorPort                  TargetPort                     Online
----- ------------------------------ ------------------------------ ------
x0005 Host_0000000100000004          iSCSI_TargetPortPR_Bh_ch8      off    <IQN>:<HOST1>
x0006 Host_0000000100000002          iSCSI_TargetPortPR_Bh_ch8      on     <IQN>:<HOST1>
x0007 Host_0000000100000002          iSCSI_TargetPortPR_Bh_ch8      on     <IQN>:<HOST1>
x0008 Host_0000000100000020          iSCSI_TargetPortPR_Bh_ch8      off    <IQN>:<HOST2>
x0009 Host_0000000100000001          iSCSI_TargetPortPR_Bh_ch7      on     <IQN>:<HOST2>
x000a Host_000000010000001f          iSCSI_TargetPortPR_Bh_ch7      off    <IQN>:<HOST1>
x000b Host_0000000100000002          iSCSI_TargetPortPR_Bh_ch8      off    <IQN>:<HOST2>
x000c Host_0000000100000001          iSCSI_TargetPortPR_Bh_ch7      on     <IQN>:<HOST2>
x000d Host_0000000100000002          iSCSI_TargetPortPR_Bh_ch8      on     <IQN>:<HOST3>
x000e Host_0000000100000002          iSCSI_TargetPortPR_Bh_ch8      on     <IQN>:<HOST3>

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.