E-Series ancient IO controller reboot during write operation to a volume
Applies to
- NetApp E-Series
- SANtricity OS 11.60.2 or later 11.60.x and 11.70.x (pre-1.70.1)
Issue
- E-Series controller resets unexpedetely. The parsed event in the
MAJOR-EVENT-LOG
of E-Series support bundle indicated the reboot reason is due toANCIENT_IO
:
B:10/23/20, 8:43:17 AM (08:43:17) 93386 4010 Controller reset - Shelf 1, Bay B
----> Reboot Reason : SCSI: REBOOT_ON_ANCIENT_IO
- Due to the unexpected controller reboot, a core dump is captured from the controller. The following signature can be found in the
excLogShow
command output and in theSTATE-CAPTURE-DATA
log file:
-- Log Entry #5 (Core 0) Jan-25-2021 09:19:30 AM ----
Reboot due to ancient IO, scsiOp=0x103265480 poolId=1 opCode=8a
age=300000ms
2021-01-25 14:08:46.129106
rebootReason 0x429c002, rebootReasonExtra 0x0