Applies to NetApp E-Series SANtricity OS 11.60.1R1 or higher Issue Controller experienced unexpected reboot for ancient I/O and triggered a core dump collection.
E-Series controller resets unexpedetely. The parsed event in the MAJOR-EVENT-LOG of E-Series support bundle indicated the reboot reason is due to ANCIENT_IO: B:10/23/20, 8:43:17 AM (08:43:17) 93386 40...E-Series controller resets unexpedetely. The parsed event in the MAJOR-EVENT-LOG of E-Series support bundle indicated the reboot reason is due to ANCIENT_IO: B:10/23/20, 8:43:17 AM (08:43:17) 93386 4010 Controller reset - Shelf 1, Bay B Due to the unexpected controller reboot, a core dump is captured from the controller. The following signature can be found in the excLogShow command output and in the STATE-CAPTURE-DATA log file: Reboot due to ancient IO, scsiOp=0x103265480 poolId=1 opCode=8a
Applies to Santricity OS 11.50.2P1 EF570 Issue E-series controller A rebooting unexpectedly due to ancient IO excLogShow output: ---- Log Entry #8 (Core 2) Dec-15-2021 02:26:30 PM ---- Reboot due to a...Applies to Santricity OS 11.50.2P1 EF570 Issue E-series controller A rebooting unexpectedly due to ancient IO excLogShow output: ---- Log Entry #8 (Core 2) Dec-15-2021 02:26:30 PM ---- Reboot due to ancient IO, scsiOp=0x1443caec0 poolId=1 opCode=2a age=300000ms