E-Series LUNs inaccessible due to fibre channel link failure between servers and storage
Applies to
- NetApp E-Series
- Brocade Switches
Issue
- Multiple windows servers failed to boot due to the boot LUN being inaccessible on the NetApp E-Series storage system.
- E-series
fcDump
output underSTATE-CAPTURE-DATA
indicates all the associated FC port link status are down on both controllers.
2806-A Our Num ::...Exchange Counts...:: Num ..Link Up..
Chip LinkStat Port Port :: :: Link Bad Bad
ID Logi ::Open Total Errors:: Down Char Frame
2-Src Down--- 27100 1 :: 0 12004199 2:: 1 0 0
3-Src Down--- 27200 1 :: 0 12094649 2:: 1 0 0
4-Src Down--- 27200 1 :: 0 11864969 5:: 1 0 0
5-Src Down--- 27100 1 :: 0 11964081 1:: 1 0 0
6-Src Down--- 27300 1 :: 0 11780361 10:: 1 0 0
7-Src Down--- 27300 1 :: 0 11887600 7:: 1 0 0
2806-B Our Num ::...Exchange Counts...:: Num ..Link Up..
Chip LinkStat Port Port :: :: Link Bad Bad
ID Logi ::Open Total Errors:: Down Char Frame
2-Src Down--- 27400 1 :: 0 14502748 5:: 1 0 0
3-Src Down--- 27400 1 :: 0 14441769 3:: 1 0 0
4-Src Down--- 27500 1 :: 0 14484567 1:: 1 0 0
5-Src Down--- 27500 1 :: 0 14345188 3:: 1 0 0
6-Src Down--- 27600 1 :: 0 14312190 0:: 1 0 0
7-Src Down--- 27600 1 :: 0 14276360 2:: 1 0 0
- E-series Major Event Log reports multiple fibre channel link down events:
B:8/14/25, 2:23:20 PM (14:23:20) 40372 1017 Fibre channel link down - Host-side: controller in bay B, port 1
B:8/14/25, 2:23:19 PM (14:23:19) 40371 1017 Fibre channel link down - Host-side: controller in bay B, port 2
B:8/14/25, 2:22:42 PM (14:22:42) 40370 1017 Fibre channel link down - Host-side: controller in bay B, port 3
B:8/14/25, 2:22:40 PM (14:22:40) 40369 1017 Fibre channel link down - Host-side: controller in bay B, port 4
B:8/14/25, 2:22:38 PM (14:22:38) 40368 1017 Fibre channel link down - Host-side: controller in bay B, port 5
B:8/14/25, 2:22:35 PM (14:22:35) 40367 1017 Fibre channel link down - Host-side: controller in bay B, port 6
A:8/14/25, 2:22:22 PM (14:22:22) 40366 1017 Fibre channel link down - Host-side: controller in bay A, port 3
A:8/14/25, 2:22:17 PM (14:22:17) 40365 1017 Fibre channel link down - Host-side: controller in bay A, port 4
A:8/14/25, 2:22:14 PM (14:22:14) 40364 1017 Fibre channel link down - Host-side: controller in bay A, port 5
A:8/14/25, 2:22:12 PM (14:22:12) 40363 1017 Fibre channel link down - Host-side: controller in bay A, port 6
- The status of FC ports on the switch associated with the affected servers and storage show
No_light
andOFFLINE