E-Series Controller redundancy lost - AutoSupport Message
Applies to
Event Summary
SANtricity reports a Controller redundancy lost
event in the Recovery GURU
Validate
MAJOR-EVENT-LOG
showsController redundancy lost
,Event type: 2829
Date/Time: <DATE/TIME>
Sequence number: 557252
Event type: 2829
Event category: Internal
Priority: Critical
Event needs attention: true
Event send alert: true
Event visibility: true
Description: Controller redundancy lost
Event specific codes: 0/0/0
Component type: Controller
Component location: Shelf 99, Bay B
Logged by: Controller in bay B
Recoveru Guru
shows that alternate contoller is inFailed
status:
Failure Entry XX: OFFLINE_CTL-Recovery Failure Type Code: 28
Storage array: <ARRAY>
Component reporting problem: Controller in bay A
Status: Failed
Location: Controller/Drive shelf 99, Controller in bay A
Replacement part number: E5700A-64GB
Board ID: 5700
Submodel ID: 360
Serial number: <SERIAL NO>
Component requiring service: Controller in bay A
Service action (removal) allowed: Yes
Service action LED on component: No
Resolution
- Place the alternate controller back online.
- If controller doesn't remain online contact NetApp Technical Support and reference this article for further assistance. The solution might require a part replacement.
- When contacting NetApp Technical Support, please provide the 7-segment code on the back display of the E-Series controller. This will help in troubleshooting the controller issue.
Additional Information
Add your text here.