E-Series detects Controller redundancy lost events due to maintenance offline
Applies to
- E-Series
 - SANtricity OS
 
Issue
- E-Series system detects following events
    
E-Series Notification (Controller redundancy lost) CRITICALE-Series Notification (Write-back caching forcibly disabled) CRITICAL
 STORAGE-ARRAY-PROFILEindicates the one controller is inFailed (Offline)status
      Controller in Shelf 99, Bay B - Unable to retrieve latest data; using last known state.
         Status:                       Failed (Offline)                
MAJOR-EVENT-LOGindicatesController reset by its alternate
Sequence number: 1403
Event type: 400F
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Controller reset by its alternate
Event specific codes: 0/0/0
Component type: Controller
Component location: Shelf 99, Bay B
Logged by: Controller in bay A
- No related error causes offline can be found
 