StorageGRID appliance reports Appliance Boot Device Fault Detected alert
Applies to
NetApp StorageGRID Appliances SG100/SG1100/SG5800/SG6000/SG6100
Issue
- StorageGRID UI reports:
-
Appliance boot device fault detected: A problem was detected with the boot device in the appliance.
-
- In StorageGRID logs for SG1X0/SG6X00, the mSATA boot device (
nvme0n1) is reported as not present:-
/var/local/kern.log-
Jan 25 13:45:54 localhost kernel: [10550998.745442] nvme nvme0: Removing after probe failure status: -19
Jan 25 13:46:24 localhost kernel: [10551029.263797] blk_update_request: I/O error, dev nvme0n1, sector 500114992 op 0x1:(WRITE) flags 0x100000 phys_seg 1 prio class 0
Jan 25 13:46:24 localhost kernel: [10551029.287110] Buffer I/O error on dev nvme0n1, logical block 62514374, lost async page write
-
-
/var/local/sys.log-
Jan 25 13:45:54 localhost kernel: [10550998.745442] nvme nvme0: Removing after probe failure status: -19
Jan 25 13:46:24 localhost kernel: [10551029.263797] blk_update_request: I/O error, dev nvme0n1, sector 500114992 op 0x1:(WRITE) flags 0x100000 phys_seg 1 prio class 0
Jan 25 13:46:24 localhost kernel: [10551029.287110] Buffer I/O error on dev nvme0n1, logical block 62514374, lost async page write
Jan 25 13:57:48 localhost kernel: [10551712.947427] sr 14:0:0:0: [sr0] CDROM not ready. Make sure there is a disc in the drive.
Jan 25 14:02:44 localhost smartd[3716]: Device: /dev/nvme0, removed NVMe device: No such device
-
-
- In StorageGRID logs for SG5800, the boot device (
sda) reporting as missing:
base-os-logs/var/local/eos-system-status"BootDevice": {"device": {"info_name": "/dev/sda1 [SAT]","name": "/dev/sda1","protocol": "ATA","type": "sat"},"device_name": "sda","sda": "missing","sda-slotname": "internal"},
/base-os-logs/var/log/syslog2025-11-28T00:58:23.283371+00:00 SG smartd[2760]: Device: /dev/sda [SAT], removed ATA device: No such device

