A single drawer failure causes Unknown state of StorageGRID storage node
Applies to
- StorageGRID appliances SG5760, SG5860, SG6000, and SG6160
- E-Series
- SANtricity OS 11.70 and later
- A failed drawer was replaced
- RAID mode is DDP16
Issue
- StorageGRID storage node is in
Unknownstatus after a replacement of failed single drawer on its storage controller - SANtricity System Manager indicates all Disk Pools and volumes are in
Failedstatus - Volume failure is detected in storage controller
E-Series Notification (Volume failure) CRITICAL
- StorageGRID Appliance Installer (
https://<APPLIANCE_IP>:8443) Home displays Start Installation

- StorageGRID Appliance Installer does not have Reboot into StorageGRID option in Advanced > Reboot Controller