Skip to main content
NetApp Knowledge Base

StorageGRID MTU size change via change-ip tool caused node reboot

Views:
77
Visibility:
Public
Votes:
0
Category:
storagegrid
Specialty:
sgrid
Last Updated:

Applies to

  • NetApp StorageGRD 11.7 .x
  • NetApp StorageGRID Appliances

Issue

Change of MTU size from 1500 to 9000 via change-ip tool caused unexpected reboot of storage node :
 
change-ip log shows:
Updating network configuration on <nodename>... FAILED.
ERROR: Net::ReadTimeout
Enter a to abort, c to continue, r to retry, f to fake success [a/c/r/f]> r
Updating network configuration on <nodename>... FAILED.
ERROR: Failed to open TCP connection to 10.x.x.x:9999 (No route to host - connect(2) for "10.x.x.x" port 9999)

 

From Support  bundle  base-os-logs/run/mount-tmp/pge-actv-root/var/log/storagegrid_crash_dmesg.DATE.log.gz:

[8752501.947268] bond0: (slave hic2): link status down for interface, disabling it in 200 ms
[8752501.955409] bond0: (slave hic3): link status up, enabling it in 200 ms
[8752501.959241] [qede_unload:3731(hic2)]Link is down
[8752501.967273] bond0: (slave hic2): link status down for interface, disabling it in 200 ms
[8752501.975420] bond0: (slave hic3): link status up, enabling it in 200 ms
[8752501.987321] divide error: 0000 [#1] SMP NOPTI
[8752501.991834] CPU: 5 PID: 0 Comm: swapper/5 Kdump: loaded Tainted: G OE 5.10.0-21-amd64 #1 Debian 5.10.162-1+ntap7
[8752502.003339] Hardware name: Default string Default string/Default string, BIOS 1.04.0 08/08/2018
[8752502.012176] RIP: 0010:qede_start_xmit+0x3e3/0xef0 [qede]
[8752502.017631] Code: a3 c7 9b c0 48 83 f8 ff 0f 84 b0 01 00 00 49 89 45 00 8b 43 38 41 83 c4 01 80 44 24 08 01 66 41 89 45 08 e9 72 ff ff ff 31 d2 <41> f7 f0 31 d2 01 c6 89 c8 41 f7 f0 29 c6 e9 09 fd ff ff 41 80 4e
[8752502.036479] RSP: 0018:ffffbed2c0218880 EFLAGS: 00010246
[8752502.041848] RAX: 0000000000000000 RBX: ffff9d7181d20780 RCX: 0000000000000000
[8752502.049118] RDX: 0000000000000000 RSI: 0000000000000000 RDI: 0000000000000000
[8752502.056386] RBP: ffff9d7f7dfc7500 R08: 0000000000000000 R09: 0000000000010000
[8752502.063653] R10: 00000000000000ce R11: 0000000000000000 R12: 0000000000000000
[8752502.070921] R13: 0000000000000000 R14: ffff9d7f7dfc7500 R15: ffff9d7112a86000
[8752502.078190] FS: 0000000000000000(0000) GS:ffff9d807df40000(0000) knlGS:0000000000000000
[8752502.086410] CS: 0010 DS: 0000 ES: 0000 CR0: 0000000080050033
[8752502.092294] CR2: 00007f5ba35eb610 CR3: 000000043d330004 CR4: 00000000003706e0
[8752502.099562] DR0: 0000000000000000 DR1: 0000000000000000 DR2: 0000000000000000
[8752502.106831] DR3: 0000000000000000 DR6: 00000000fffe0ff0 DR7: 0000000000000400
[8752502.114100] Call Trace:

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.