Skip to main content
NetApp Knowledge Base

What is the correct order to power on/off StorageGRID nodes when performing a MetroCluster switchover

Views:
44
Visibility:
Public
Votes:
0
Category:
storagegrid
Specialty:
sgrid
Last Updated:

Applies to

  • Netapp StorageGRID
  • MetroCluster

Answer

  • StorageGRID nodes should be powered off before shutting down any  ONTAP node to avoid alerts being triggered. 
  • StorageGRID nodes should be powered on and all services running before powering on any ONTAP nodes on the new site. 
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.