StorageGRID Appliance NIC fault detected - AutoSupport Message
Applies to
- NetApp StorageGRID
- Software release 11.7 +
Event Summary
- StorageGRID Grid Manager reports the following alert: Appliance NIC fault detected – A problem with a network interface card (NIC) in the appliance was detected.
- ASUP generated Alert in case:
StorageGRID Notification from GRIDID(HARDWARE FAILURE - Component: NIC, Slot: hic3, PartNumber: X1158A)
nicName: hic3, nicDescription: ConnectX-6 Lx EN adapter card, 25GbE, Dual-port SFP28, PCIe 4.0 x8, No Crypto, nicSerialNumber: MT2439J01T3R, nicFirmwareVersion: 26.39.1002 (MT_0000000531), componentMarketingPartNumber: X90-SG6000-HBA-FC, component3x5PartNumber: 106-00289, hardwarePlatform: SGF6112
Validate
- Login to the StorageGRID Grid Manager, and confirm the "Appliance NIC fault detected – A problem with a network interface card (NIC) in the appliance was detected" is present under Alerts section.
- Verify what errors are seen on hic with following commands:
ifconfig <hic>
ethtool -S <hic>
- Verify what errors are seen on hic with following commands:
Resolution
- Reseat the NIC. Refer to the maintenance instructions for your appliance for detailed steps.
Additional Information
Please refer to the appropriate hardware procedure guide for your appliance: