ESXi datastores not accessible with error "device entered the All Paths Down state"
Applies to
- VMware ESXi all versions
- ONTAP 9
Issue
- All paths down reported by host and lost access to storage
- Error message(s) seen in the host logs:
cpu34:33313)StorageApdHandler: 982: APD Handle Created with lock[StorageApd-0x43041149xxb0]
[APDCorrelator]:[vob.storage.apd.start] Device or filesystem with identifier [x] has entered the All Paths Down state.
[APDCorrelator]:[esx.problem.storage.apd.start] Device or filesystem with identifier [x] has entered the All Paths Down state.
- ESX Datastores seeing the numerous Path redundancy to storage device
naa.600a0980383x363644xxf41354x6773
degraded. Pathvmxba1:C0:Tx44:L100
is down. Affected datastores:EsxHxxPrdVxiOs900_ushouxxor1011
- Below login events for observed in EMS logs for the affected host initiators:
Tue Nov 14 07:08:14 -0600 [ushouxxtor10-09: fct_tpd_work_thread_0: scsitarget.fct.portLogin:notice]: Login at target FC port: '2a' by initiator port: '20:0x:0x:25:bx:02:a0:76' address 0xe80xx6. The target virtual port is: 'NetApp FC Target Port (LPe32000) ushoxxtor1011-EsxVxi:ushoxxtor10-0x_fx_lif_1'.
Tue Nov 14 07:08:14 -0600 [ushouxxor10-09: fct_tpd_work_thread_0: scsitarget.fct.portLogin:notice]: Login at target FC port: '4a' by initiator port: '20:0x:0x:2x:bx:02:a0:76' address 0xe80xx6. The target virtual port is: 'NetApp FC Target Port (LPe32000) ushoxxtor1011-EsxVxi:ushoustor10-0x_fx_lif_3
IO WQE
errors with extended status 16 is observed in ems logs:
Tue Nov 14 07:08:19 -0600 [ushxxstor10-09: fct_tpd_work_thread_0: fcp.io.status:debug]: STIO Adapter:2b IO WQE failure, Handle 0x3, Type 8, S_ID: C8xx92, VPI: 279, OX_ID: 472A, Status 0x3 Ext_Status 0x16
- From
vobd
host logs path changed from dead errors observed:
2023-11-14T14:16:43.461Z: [scsiCorrelator] 6940447943826us: [vob.scsi.scsipath.pathstate.on] scsiPath vmhba2:C0:T14x:L100 changed state from dead
2023-11-14T14:16:43.485Z: [scsiCorrelator] 6940447967687us: [vob.scsi.scsipath.add] Add path: vmhba2:C0:T16x:L100
2023-11-14T14:16:43.492Z: [scsiCorrelator] 6940447974351us: [vob.scsi.scsipath.pathstate.on] scsiPath vmhba2:C0:T16x:L100 changed state from dead
2023-11-14T14:16:43.540Z: [scsiCorrelator] 6940448022605us: [vob.scsi.scsipath.add] Add path: vmhba2:C0:T14x:L100
2023-11-14T14:16:43.551Z: [scsiCorrelator] 6940448033745us: [vob.scsi.scsipath.pathstate.on] scsiPath vmhba2:C0:T14x:L100 changed state from dead
- Below steps can be verified that might trigger the APD state of the storage device:
- Possible fabric issues
- Verify end to end connectivity
- Verify all end port states
- Check for underlying Performance issues