Storage Replication Adapter (SRA): Failed to configure access to recovered device
- Views:
- 32
- Visibility:
- Public
- Votes:
- 0
- Category:
- ontap-storage-replication-adapter
- Specialty:
- virt
- Last Updated:
Applies to
- ONTAP Storage Replication Adapter (SRA) 9.13P1
- VMware Site Recovery Manager (SRM)
Issue
- Running a recovery plan with multiple LUNs in SRM fails with the following error:
Error: Failed to recover datastore '<datastore>'.
Failed to configure access to recovered device '//<device>'.
- If the recovery plan is run again later, the plan succeeds.
- In the SRA
vvolvp.log
file, there are errors similar to the following:
Unable to map LUN. Failed with exception Caused by: Failed to create igroup failover_igroup_domain-c#### type vmware.Initiator group already exists (errno=9004)
- In the
vvolvp.log
file, you can see the same igroup created successfully prior to the to mapping error:
Created igroup failover_igroup_domain-c#### with initiators […]