Applies to AFF-A700 FAS9000 Issue After a power outage the node reports warning during the first boot WARNING: The NVRAM DIMM1 has caused UECC in the past. WARNING: The NVRAM DIMM2 has caused UECC in ...Applies to AFF-A700 FAS9000 Issue After a power outage the node reports warning during the first boot WARNING: The NVRAM DIMM1 has caused UECC in the past. WARNING: The NVRAM DIMM2 has caused UECC in the past. Please replace it as soon as possible!!! *******************************************************
In some rare circumstances customers may want to change the IOPS on the AWS CVO NVRAM disk (can be shared with boot disk). Typically this is only in response to working with the Performance team in Ne...In some rare circumstances customers may want to change the IOPS on the AWS CVO NVRAM disk (can be shared with boot disk). Typically this is only in response to working with the Performance team in NetApp Support or a NetApp architect/Cloud resource. Note: The IOPS on the boot disk can be increased on a running system without any negative impact. Example: The boot disk is identified by EBS volume mounted on /dev/sda1 to the EC2 instance as shown in the screenshot below.
Applies to NetApp Element software Issue Metadata drive is constantly being ejected Slice service unhealthy after adding metadata drive NVRAM Partition not mounted NVRAM device critical={Device: 0x100...Applies to NetApp Element software Issue Metadata drive is constantly being ejected Slice service unhealthy after adding metadata drive NVRAM Partition not mounted NVRAM device critical={Device: 0x1000004 Key: armStatusSaveNArmed, Device: 0x1000004 Key: notEnoughEnergyForCatastrophicSave}
Applies to FAS9000 AFF-A700 Issue After replacing NVDIMM on FAS9000 / AFF-A700, 'Data loss is likely' seen on boot ****************************************************************** * CRITICAL ERROR *...Applies to FAS9000 AFF-A700 Issue After replacing NVDIMM on FAS9000 / AFF-A700, 'Data loss is likely' seen on boot ****************************************************************** * CRITICAL ERROR * * NVRAM has detected errors. Ontap cleared the error. * * Data loss is likely. * ******************************************************************
Applies to SF9605 Issue When booting up a node, boot stops with UEFI0067 error code: UEFI0067: A PCIe link training failure is observed in PCIe Slot 3 and the link is disabled. Check Additional Inform...Applies to SF9605 Issue When booting up a node, boot stops with UEFI0067 error code: UEFI0067: A PCIe link training failure is observed in PCIe Slot 3 and the link is disabled. Check Additional Information section for full screenshot
Azure CVO instance shut down and won't boot back into ONTAP. When attempting to boot, it shuts itself down again. The Azure console reports the following upon boot up: PANIC: NVRAM jettison for dirty ...Azure CVO instance shut down and won't boot back into ONTAP. When attempting to boot, it shuts itself down again. The Azure console reports the following upon boot up: PANIC: NVRAM jettison for dirty shutdown of panic-mode vsim/vsa. in SK process rc on release 9.8P1 (C) on Thu Sep 23 17:45:53 GMT 2021 Writing panic info to HA mailbox disks. HA: current time (in sk_msecs) 10145 (in sk_cycles) 379727184508 coredump: warning: dump is aborted because a core in the dump device is not saved yet.
Applies to Cloud Volumes ONTAP (CVO) High Availability (HA) Amazon Web Services (AWS) Issue When CVO is used in an HA configuration on AWS with ONTAP 9.8 or earlier, increased NVRAM latency may be obs...Applies to Cloud Volumes ONTAP (CVO) High Availability (HA) Amazon Web Services (AWS) Issue When CVO is used in an HA configuration on AWS with ONTAP 9.8 or earlier, increased NVRAM latency may be observed